Long modal interference in multimode fiber and its application in vital signs monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(7 citation statements)
references
References 30 publications
0
6
0
Order By: Relevance
“…Since the effective components of the heartbeat signal with an HR of 50-110 bpm were mainly concentrated in the range of 0.8-1.8 Hz, a zero-phase bandpass filter with a frequency of 0.8-1.8 Hz was used for the recovery, as shown in Figure 7c. More importantly, different from the other type of RR and HR optical fiber sensors [7,12,19,21], owing to the combined advantages of the high bending sensitivity of the SHMF-MZI and the optimized designation of the microbending deformer, the amplitude of the extracted HR signal was comparable with that of the extracted RR.…”
Section: Hr and Rr Monitoring Experimentsmentioning
confidence: 71%
See 3 more Smart Citations
“…Since the effective components of the heartbeat signal with an HR of 50-110 bpm were mainly concentrated in the range of 0.8-1.8 Hz, a zero-phase bandpass filter with a frequency of 0.8-1.8 Hz was used for the recovery, as shown in Figure 7c. More importantly, different from the other type of RR and HR optical fiber sensors [7,12,19,21], owing to the combined advantages of the high bending sensitivity of the SHMF-MZI and the optimized designation of the microbending deformer, the amplitude of the extracted HR signal was comparable with that of the extracted RR.…”
Section: Hr and Rr Monitoring Experimentsmentioning
confidence: 71%
“…This included meticulous daily measurements on two volunteers, conducted over a period of five consecutive days. In order to evaluate the accuracy of the wearable SHMF-MZI microbend sensor, a commercial device called Oxygen Saturation (SpO2) sensor was selected for the simultaneous measurement of HR [7], and the RR measurement results were compared with the manual counting method. The respiratory and heartbeat signals of 10 volunteers (5 males and 5 females) were collected in the experiments; all of them did not have any cardiac diseases or take any hormonal drugs prior to the test.…”
Section: Hr and Rr Monitoring Experimentsmentioning
confidence: 99%
See 2 more Smart Citations
“…Vital sign monitoring plays a crucial role in both prevention and diagnosis of various health problems [ 135 , 136 ]. As more and more people pay attention to their health condition, various measurement systems are developed, in particular, following the so-called “wearable” concept.…”
Section: Interference and Signal Pre-processingmentioning