2021
DOI: 10.1016/j.pacs.2020.100230
|View full text |Cite
|
Sign up to set email alerts
|

Long-distance in-situ methane detection using near-infrared light-induced thermo-elastic spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 38 publications
(13 citation statements)
references
References 25 publications
(20 reference statements)
1
10
0
Order By: Relevance
“…The optimal position of QTF was experimentally chosen by observation of the 2f signal amplitude registered for a 2000 ppmv (parts per million by volume) mixture of CH 4 and nitrogen (N 2 ), with special attention paid to both the signal amplitude and the signal oscillations that occur with suboptimal QTF settings (optical fringe caused by back-reflections from the silver layer on the QTF). Changing the illumination position can to some extent affect the level of thermal noise generated by the quartz resonator [ 41 , 42 ]. In the case of the presented system, the maximum signal-to-noise ratio occurred at a point of maximum 2f signal amplitude.…”
Section: Methodsmentioning
confidence: 99%
“…The optimal position of QTF was experimentally chosen by observation of the 2f signal amplitude registered for a 2000 ppmv (parts per million by volume) mixture of CH 4 and nitrogen (N 2 ), with special attention paid to both the signal amplitude and the signal oscillations that occur with suboptimal QTF settings (optical fringe caused by back-reflections from the silver layer on the QTF). Changing the illumination position can to some extent affect the level of thermal noise generated by the quartz resonator [ 41 , 42 ]. In the case of the presented system, the maximum signal-to-noise ratio occurred at a point of maximum 2f signal amplitude.…”
Section: Methodsmentioning
confidence: 99%
“…LITES technology overcomes the above limitation well. The detection module can be placed far away from the environment to be tested, so that QTF will not be affected [23][24][25][26][27] . In LITES, after being absorbed by target gas, the laser is irradiated on the crystal surface of QTF.…”
Section: Introductionmentioning
confidence: 99%
“…After absorbed by target gas, the modulated beam laser hits the QTF surface generating a modulated localized heating. The temperature changes in QTF induced by photothermal conversion results in thermoelastic expansion and contraction [24] , [25] , [26] , [27] , [28] . These light-induced deformations, once again, generate a charge distribution that can be collected by the metal pattern, generating an electrical signal which results proportional to the portion of absorbed light from the gas sample.…”
Section: Introductionmentioning
confidence: 99%