2018
DOI: 10.1039/c8an01661e
|View full text |Cite
|
Sign up to set email alerts
|

Logical MS/MS scans: a new set of operations for tandem mass spectrometry

Abstract: Described herein are novel sets of multiplexed MS/MS scans – termed ‘logical scans’ – performed on a linear ion trap.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
13
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 12 publications
(15 citation statements)
references
References 67 publications
2
13
0
Order By: Relevance
“…Alternative pulse sequences using stored waveform ion radius modulation (SWIM) enable the development of 2D MS in mass analysers other than the FT-ICR MS (Ross et al 1993 , 2002 ; van Agthoven and O’Connor 2017 ). Techniques that approach 2D MS are being developed for quadrupolar ion traps (Snyder et al 2018 ). Non-uniform sampling acquisition has been shown to increase resolving power and shorten experiment durations (Bray et al 2017 ).…”
Section: Resultsmentioning
confidence: 99%
“…Alternative pulse sequences using stored waveform ion radius modulation (SWIM) enable the development of 2D MS in mass analysers other than the FT-ICR MS (Ross et al 1993 , 2002 ; van Agthoven and O’Connor 2017 ). Techniques that approach 2D MS are being developed for quadrupolar ion traps (Snyder et al 2018 ). Non-uniform sampling acquisition has been shown to increase resolving power and shorten experiment durations (Bray et al 2017 ).…”
Section: Resultsmentioning
confidence: 99%
“…Automated peak-assignment algorithms are being developed for routine analysis [26]. A pulse sequence for 2D MS in a linear ion trap has been proposed, which expands the potential of 2D MS to mass analyzers beyond FT-ICR MS [27][28][29]. Nevertheless, the question of how to improve the signal-to-noise ratio and the resolving power of 2D mass spectra remains.…”
Section: Introductionmentioning
confidence: 99%
“… 21 Logical operations can be performed by combining scans, in particular, the AND/OR operation can be performed by simultaneously performing two scans. 22 These simultaneous scans can be tailored for certain analytes, and in this study, we show how the combinations of scans, specifically (i) two precursor scans and (ii) a precursor and a neutral loss scan can be tailored to prioritize quantitative precision or detection limits, respectively. The latter combination scan, because of its lower detection limit using benchtop instrumentation, was then implemented on a miniature mass spectrometer to demonstrate the feasibility of detection of such antibiotics on-site at concentrations of practical significance.…”
Section: Introductionmentioning
confidence: 93%