2013
DOI: 10.2337/dc12-0584
|View full text |Cite
|
Sign up to set email alerts
|

LOGIC-Insulin Algorithm–Guided Versus Nurse-Directed Blood Glucose Control During Critical Illness

Abstract: OBJECTIVETight blood glucose control (TGC) in critically ill patients is difficult and labor intensive, resulting in poor efficacy of glycemic control and increased hypoglycemia rate. The LOGIC-Insulin computerized algorithm has been developed to assist nurses in titrating insulin to maintain blood glucose levels at 80–110 mg/dL (normoglycemia) and to avoid severe hypoglycemia (<40 mg/dL). The objective was to validate clinically LOGIC-Insulin relative to TGC by experienced nurses.RESEARCH DESIGN AND METHODSTh… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

2
84
2
5

Year Published

2014
2014
2023
2023

Publication Types

Select...
5
2
2

Relationship

2
7

Authors

Journals

citations
Cited by 88 publications
(93 citation statements)
references
References 39 publications
2
84
2
5
Order By: Relevance
“…This simulation study, which used true clinical data from critically ill patients in whom TGC was done by the LOGIC-Insulin control system (21 ), showed that less stringent allowable error criteria may be needed for continuous than for intermittent glucose sensors. It also confirms the conclusion by Boyd and Bruns that quality specifications of intermittent glucose sensors may be different for CGM devices (20 ).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…This simulation study, which used true clinical data from critically ill patients in whom TGC was done by the LOGIC-Insulin control system (21 ), showed that less stringent allowable error criteria may be needed for continuous than for intermittent glucose sensors. It also confirms the conclusion by Boyd and Bruns that quality specifications of intermittent glucose sensors may be different for CGM devices (20 ).…”
Section: Discussionmentioning
confidence: 99%
“…Recently, we clinically validated the LOGICInsulin blood glucose algorithm in an RCT (21 ). This software system, incorporating an advanced algorithm (22 ), advises the bedside nurse on insulin dosage (or glucose bolus in the event of hypoglycemia) and the timing of the next blood sampling.…”
mentioning
confidence: 99%
“…In this regard, model-based glycaemic control methods have recently shown good safety and performance [28][29][30][31][32][33]. Their main advantage is the use of a computer model to identify patient-specific insulin sensitivity (SI), which quantitatively describes patient response to insulin.…”
mentioning
confidence: 99%
“…8 In the LOGIC-Insulin algorithm study, patients in the CIIP group experienced significantly less mild (BG < 70 mg/dL) moderate (BG < 60 mg/dL) and severe hypoglycemia (BG < 40 mg/dL) in comparison to patients treated with a paper-based insulin infusion protocol, while both groups achieved similar mean BG levels. 9 Comparable BG control with a reduction in the incidence of hypoglycemia was reported in other studies comparing computerized to paper-based insulin infusion protocols. [10][11][12] In January 2013 we converted all 4 adult ICUs in our hospital (2 medical and 2 surgical) to a CIIP.…”
mentioning
confidence: 67%