Localized B0 shimming based on 23Na MRI at 7 T

Abstract: To validate the feasibility of localized B 0 shimming based on B 0 maps acquired with sodium (23 Na) MRI. Methods: A localized B 0 shimming routine based on a constrained regularized algorithm in combination with 23 Na MRI data acquired with a 3D density-adapted radial readout scheme was implemented on a 7T MR system. Measurements were performed using a dual-tuned 23 Na/ 1 H head coil. The quality of B 0 maps reconstructed from 23 Na images and the resulting shim values was examined depending on the acquisitio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
6
1

Relationship

5
2

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 21 publications
0
3
0
Order By: Relevance
“…To reduce motion effects during the acquisition, several cushions were used to fix the position of the leg within the 23 Na/ 39 K RF coil. Before 23 Na/ 39 K MRI measurements, B 0 shimming was performed based on 23 Na MRI data in combination with a constrained regularized algorithm 24 . Quantitative 39 K and 23 Na MRI data were acquired using a 3D acquisition-weighted stack-of-stars (AW-SOSt) sequence applying a nonselective excitation pulse 25 .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…To reduce motion effects during the acquisition, several cushions were used to fix the position of the leg within the 23 Na/ 39 K RF coil. Before 23 Na/ 39 K MRI measurements, B 0 shimming was performed based on 23 Na MRI data in combination with a constrained regularized algorithm 24 . Quantitative 39 K and 23 Na MRI data were acquired using a 3D acquisition-weighted stack-of-stars (AW-SOSt) sequence applying a nonselective excitation pulse 25 .…”
Section: Methodsmentioning
confidence: 99%
“…Before 23 Na/ 39 K MRI measurements, B 0 shimming was performed based on 23 Na MRI data in combination with a constrained regularized algorithm. 24 Quantitative 39 K and 23 Na MRI data were acquired using a 3D acquisition-weighted stack-of-stars (AW-SOSt) sequence applying a nonselective excitation pulse. 25 Most relevant MRI measurement parameters are summarized in Table 1.…”
mentioning
confidence: 99%
“…The B 0 inhomogeneity was corrected by calculating the 23 Na Δ B 0 maps as described in Gast et al 22 Here, the 23 Na Δ B 0 maps were calculated based on the first two 23 Na-MRSI phase-unwrapped images (…”
Section: Post-processingmentioning