2011
DOI: 10.1016/j.ijrobp.2010.07.1980
|View full text |Cite
|
Sign up to set email alerts
|

Local Setup Errors in Image-Guided Radiotherapy for Head and Neck Cancer Patients Immobilized With a Custom-Made Device

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
20
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 28 publications
(21 citation statements)
references
References 14 publications
1
20
0
Order By: Relevance
“…The patients were treated postoperatively for oropharyngeal cancer or received definitive radiation therapy for locally advanced hypopharyngeal cancer. To reduce pose variation all patients were immobilized with a customized scotch-cast head mask and a vacuum pillow [10]. A stereotactic head frame was used for daily positioning and image guidance was applied with an in-room, on-rails, single slice spiral CT-scanner (Primatom, Siemens, Erlangen).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The patients were treated postoperatively for oropharyngeal cancer or received definitive radiation therapy for locally advanced hypopharyngeal cancer. To reduce pose variation all patients were immobilized with a customized scotch-cast head mask and a vacuum pillow [10]. A stereotactic head frame was used for daily positioning and image guidance was applied with an in-room, on-rails, single slice spiral CT-scanner (Primatom, Siemens, Erlangen).…”
Section: Methodsmentioning
confidence: 99%
“…Reasons for this uncertainties are mainly setup errors of the positioning devices [9], pose variations due to different bone and joint positions, soft tissue shift caused by muscle and organ activites as well as weight loss of the patients [1013]. While rigid setup uncertainties can be compensated with rigid treatment couch corrections calculated from fraction control CT images in image guided radiation therapy (IGRT) [14], the remaining anatomical deformations of the tumor shape can compromise the dose coverage of the CTV [15,16].…”
Section: Introductionmentioning
confidence: 99%
“…Patients were positioned using a stereotactic setup. Both, fixation and positioning setup have been described previously [4]. …”
Section: Methodsmentioning
confidence: 99%
“…It is deduced from a cohort of 45 patients. The additional margin amounts for 4 mm [4]. The margin is derived from local positioning uncertainties of the CTV region, however, in this study it is also applied to the eCTV to approximate the actually required margin.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation