Local Inductive Heating Method Using Novel High-Temperature Implant for Thermal Treatment of Luminal Organs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(13 citation statements)
references
References 16 publications
0
13
0
Order By: Relevance
“…This is an implanted device with which treatment can be done multiple times once the implant is in place, which may make it useful in the treatment of large or recurrent tumours. The technique used in this thermal ablation device also has the advantage that it can be applied to implants of various shapes, including stent-like and plate implants [14]. In addition to ablation treatment, it may also be possible to use the device in heat therapy for hollow viscera or blood vessels.…”
Section: Discussionmentioning
confidence: 99%
“…This is an implanted device with which treatment can be done multiple times once the implant is in place, which may make it useful in the treatment of large or recurrent tumours. The technique used in this thermal ablation device also has the advantage that it can be applied to implants of various shapes, including stent-like and plate implants [14]. In addition to ablation treatment, it may also be possible to use the device in heat therapy for hollow viscera or blood vessels.…”
Section: Discussionmentioning
confidence: 99%
“…The dimensions and schematic details of the shielding plate for analyzing the magnetic field intensity of various materials are shown in Figure 2. Figure 2 represents the model of rectangular shield plate and distance to measure the intensity of the magnetic field [31,33]. After that, we analyzed the effectiveness of magnetic field shielding (SE) of various materials in the following equation [34].…”
Section: Concept and Construction Of Shielding Systemmentioning
confidence: 99%
“…From Table 2, we found that the aperture size of 8 centimeters can perform the best results because the electric loss density is high. Furthermore, it can control the leakage of the magnetic field or the effectiveness of magnetic field shielding (SE) more effectively [33]. Considering the results of Table 2 shows that the aperture sizes of 9 and 10 centimeters the electric loss density are having highly values.…”
Section: Evaluating Electric Loss Densitymentioning
confidence: 99%
“…Typically, the local temperature surrounding the treated region is maintained under 44 • C to avoid collateral damages, and the body temperature is maintained below 42 • C to make the patient feel comfortable. Different types of HT techniques have been proposed, including capacitive [3], inductive [4], phased array [5], ultrasound [6] and interstitial [7]. Typical operating frequencies include 1-300 MHz in the RF band and 300 MHz-300 GHz in the microwave band [8]; 5 kHz-1 MHz for inductive HT [8], 5-430 MHz for capacitive HT [9], and 70-2,450 MHz for phased-array HT [10].…”
Section: Introductionmentioning
confidence: 99%