2020
DOI: 10.1016/j.msec.2019.110402
|View full text |Cite
|
Sign up to set email alerts
|

Local extraction and detection of early stage breast cancers through a microneedle and nano-Ag/MBL film based painless and blood-free strategy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
26
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 38 publications
(26 citation statements)
references
References 43 publications
0
26
0
Order By: Relevance
“…Wang and co‐workers combined MNs, silver (Ag) nanomaterials, and thin films for semi‐quantitative detection of breast cancer at its early stage. [ 92 ] MNs were first used to pierce the epidermis of the mammary gland skin, and the synthesized MBL membrane (a modified pectin film) was then covered on the surface to extract and collect the extrudated tissue fluid. After being labeled by Ag 3 PO 4 /Ag nanocomposite, the carcino‐embryonic antigen (CEA), a typical tumor marker, on the membrane could be detected via a nano‐Ag‐based magnetic colorimetric sensing platform.…”
Section: Diagnostic Applications Of Mns Integrated With Npsmentioning
confidence: 99%
“…Wang and co‐workers combined MNs, silver (Ag) nanomaterials, and thin films for semi‐quantitative detection of breast cancer at its early stage. [ 92 ] MNs were first used to pierce the epidermis of the mammary gland skin, and the synthesized MBL membrane (a modified pectin film) was then covered on the surface to extract and collect the extrudated tissue fluid. After being labeled by Ag 3 PO 4 /Ag nanocomposite, the carcino‐embryonic antigen (CEA), a typical tumor marker, on the membrane could be detected via a nano‐Ag‐based magnetic colorimetric sensing platform.…”
Section: Diagnostic Applications Of Mns Integrated With Npsmentioning
confidence: 99%
“…The intensity of the blue color is related to the target concentration. Chen et al developed a colorimetric method for early breast cancer detection [120]. Solid MN was adopted to insert into tumor tissue, while ISF was collected through a synthetic breathable thin membrane by siphon effect.…”
Section: Colorimetric Determinationmentioning
confidence: 99%
“…Recently, MN platforms for bio-uid extraction and biomarker detection via colorimetric reactions attracted signicant interest, especially as they bypass the need for complex in-lab apparatus, and pave the way for future use in self-diagnosis at home. [101][102][103] He et al developed a hydrogel MN patch made of polyvinyl alcohol (PVA) and chitosan (CS) for point-of-care testing. Aer the extraction process, the target biomarkers from the MN patch were rapidly recovered by gentle heating because the PVA/CS hydrogel is water-soluble at higher temperatures.…”
Section: Detection and Diagnosis Using Mnsmentioning
confidence: 99%