2015
DOI: 10.1016/j.corsci.2015.06.004
|View full text |Cite
|
Sign up to set email alerts
|

Local electrochemistry of reinforcement steel – Distribution of open circuit and pitting potentials on steels with different surface condition

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
24
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 39 publications
(25 citation statements)
references
References 18 publications
0
24
0
1
Order By: Relevance
“…200 mV, immersion in an alkaline solution reduced this inhomogeneity to ca. 20 mV within one day (measured after removal from solution) [29]. This indicates relatively fast transformation, i.e.…”
Section: Native Rust Layersmentioning
confidence: 89%
See 1 more Smart Citation
“…200 mV, immersion in an alkaline solution reduced this inhomogeneity to ca. 20 mV within one day (measured after removal from solution) [29]. This indicates relatively fast transformation, i.e.…”
Section: Native Rust Layersmentioning
confidence: 89%
“…Stefanoni et al [29] measured local open circuit potentials of individual points on the surface of ''asreceived'' reinforcement steels by locally contacting the steel with a test electrolyte and an electrochemical sensor. Surfaces with only black mill-scale or rebars that were severely pre-rusted (entire surface covered with rust) showed a narrow distribution of local open circuit potentials (standard deviation ca.…”
Section: Native Rust Layersmentioning
confidence: 99%
“…It is believed that the Fe 2+ /Fe 3+ couple present on the steel surface strongly dominated the potential of the rebars. It has been reported that rusted steel has a 10 times higher cathodic oxygen reduction current compared to steel with mill scale [29]. This was explained by the fact that the sites for oxygen reduction are reduced by -FeOOH crystals -the more rust is available to be reduced the more intense is the cathodic oxygen reduction [30].…”
Section: Experiences Madementioning
confidence: 99%
“…6) may be explained by properties of both the steel and the concrete. A current study presented at this conference [8] using local electrochemical measurements [9] has revealed large differences in electrochemical properties of the steel surface between locations on or between ribs. Local concrete properties may also be influenced by the rebar geometry for instance regions of plastic settlement below a rib (vertical rebars), which, similar to the bleedwater zone below horizontal bars [10][11][12][13], may promote corrosion initiation [14].…”
Section: Steel Surfacementioning
confidence: 99%