2015
DOI: 10.2172/1375378
|View full text |Cite
|
Sign up to set email alerts
|

Loads as a Resource: Frequency Responsive Demand

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2015
2015
2018
2018

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(7 citation statements)
references
References 10 publications
0
7
0
Order By: Relevance
“…Fast response (Fast Resp)-ability to respond in seconds up to 5 min. This response encompasses primary and secondary frequency response 3 . "Fast Response" of difference devices is analyzed and assigned one of three levels (High, Med, Low) in Table 1 based on analysis presented below the table; 3.…”
Section: 2mentioning
confidence: 99%
See 1 more Smart Citation
“…Fast response (Fast Resp)-ability to respond in seconds up to 5 min. This response encompasses primary and secondary frequency response 3 . "Fast Response" of difference devices is analyzed and assigned one of three levels (High, Med, Low) in Table 1 based on analysis presented below the table; 3.…”
Section: 2mentioning
confidence: 99%
“…As shown in Table 1, most devices can provide fast response needed for primary frequency response. Any device could be equipped with sensors and intelligence to monitor grid frequency and to drop load in the event of a frequency drop [3], [69]. This approach for engaging small DER for primary frequency response may become more important as DER replace large generators which are currently relied on for primary frequency response.…”
Section: Summary and Looking Forwardmentioning
confidence: 99%
“…The optimal controller gains were determined based on decentralized robust control theory, while the switching probabilities of individual TCLs were designed using Markov chain models. In FY14, this control strategy was further extended in [2] so that only local frequency measurements are required and the topology of the power system network can be fully respected. The effectiveness of this approach was demonstrated by large-scale simulation studies on the WECC system using PowerWorld Simulator.…”
Section: Executive Summarymentioning
confidence: 99%
“…In particular, the performance of the GFAs was evaluated in terms of the response time, geographical location, and penetration level. In FY14, the feasibility of using the GFA controller to provide primary frequency response was investigated in [2]. In particular, the impacts of GFAs on the system frequency response were analyzed by examining the curtailing frequency threshold, which determines the capability of GFAs in providing frequency response.…”
Section: Executive Summarymentioning
confidence: 99%
See 1 more Smart Citation