2016
DOI: 10.1049/iet-gtd.2015.0131
|View full text |Cite
|
Sign up to set email alerts
|

Load following mechanism and power flow algorithm under generator rotor angle control mode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…Due to the great technological advance applied in the development of new PMUs with the ability to measure the rotor angle with good precision, today new proposals are under development for implementing methodologies for the control of electrical power systems, such as the D_LFC scheme analyzed in [15]. This decentralized scheme is based on a consensus that depends on the fact that each generator is locally provided with a PMU with the capacity to measure its internal rotor angle δ to be compared to the reference value δref$\delta _{ref}$.…”
Section: Proposed Methodologymentioning
confidence: 99%
See 1 more Smart Citation
“…Due to the great technological advance applied in the development of new PMUs with the ability to measure the rotor angle with good precision, today new proposals are under development for implementing methodologies for the control of electrical power systems, such as the D_LFC scheme analyzed in [15]. This decentralized scheme is based on a consensus that depends on the fact that each generator is locally provided with a PMU with the capacity to measure its internal rotor angle δ to be compared to the reference value δref$\delta _{ref}$.…”
Section: Proposed Methodologymentioning
confidence: 99%
“…Thus, [13] proposes a methodology for the implementation of decentralized controllers that are synchronized by a second-order consensus. Wei et al, in several articles [10,14,15], proposes the concept of introducing the measurement of the internal rotor angle and establishes its principles to implement a local controller within the governor that can return the frequency to its nominal value after an event of deviation between demand and generation. However, for the implementation of his proposal, a complete observability of the system is required, thus there is a need to install PMUs in all the generation units, being an expensive solution.…”
Section: Introductionmentioning
confidence: 99%
“…On the one hand, energy consumption and emissions can be reduced in the short term through the power-saving dispatch of power plants. On the other hand, in the process of investing in power generation, the introduction of energy-saving and emissionreduction technologies to maximize the elimination of backward production capacity (Wei et al, 2016) has a profound impact on the development of enterprises. The implementation of the energy-saving power generation plan will greatly change the profit distribution of the country's power generation industry, and will also have a certain impact on power grid companies and users.…”
Section: Energy-saving Power Generation Scheduling Analysismentioning
confidence: 99%