Load-Carrying Capacity of Double-Shear Bolted Connections with Slotted-In Steel Plates in Squared and Round Timber Based on the Experimental Testing, European Yield Model, and Linear Elastic Fracture Mechanics

Abstract: Nowadays, the use of timber as a building material is gaining more prominence. When designing timber structures, it is necessary to pay increased attention to the design of their connections. The commonly used connections are dowel-type connections, which are often used in combination with steel plates slotted into cut-outs in timber members. The presented paper deals with the behavior of double-shear bolted connections of squared timber and round timber with slotted-in steel plates. Several variants of connec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 30 publications
0
4
0
Order By: Relevance
“…The strength of the vast majority of the tested specimens reported in the literature was dictated by premature failure modes [ 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 ]. In fact, the mechanisms that occurred in most of the experimental tests were concrete pry-out failure, concrete splitting, concrete breakout, concrete edge failure, or anchor failure.…”
Section: Comparison Between Model Results and Tests Results Borrowed ...mentioning
confidence: 99%
See 1 more Smart Citation
“…The strength of the vast majority of the tested specimens reported in the literature was dictated by premature failure modes [ 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 ]. In fact, the mechanisms that occurred in most of the experimental tests were concrete pry-out failure, concrete splitting, concrete breakout, concrete edge failure, or anchor failure.…”
Section: Comparison Between Model Results and Tests Results Borrowed ...mentioning
confidence: 99%
“…Moreover, the phenomena that have been investigated for cast-in and post-installed shear anchors are premature failure modes, i.e., concrete edge failure, concrete splitting, anchor failure, concrete breakout, concrete pry-out failure, cyclic load failure, collapse due to prying actions [ 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 ]. Conversely, strength dictated by the concrete that surrounds the anchors by a pure shear mechanism has not been investigated, although this failure mode is the one that provides the greatest strength, so it should be the aim of anchor design as long as the geometric conditions allow it.…”
Section: Introduction: State-of-the-art About Post-installed Concrete...mentioning
confidence: 99%
“…Thus, the safety of glulam beam-column structure mainly depends on the bearing capacity of connections in timber structures. Connections in glulam beamcolumn structure are generally connected by steel plates and bolts [3][4][5]. The bolted connections characterized by clear force transmission and easy installation [6] have some moment-resisting capacities.…”
Section: Introductionmentioning
confidence: 99%
“…It can be an excellent tool for the understanding of the behavior of connections in timber structures. Dobeš 2022 [ 35 ], Braun 2022 [ 36 ], and Kupniewska 2021 [ 37 ] dealt with the calibration and validation of numerical models according to experimental tests.…”
Section: Introductionmentioning
confidence: 99%