Live demonstration: Femto-to-macro scale interdisciplinary sensing with tensioned metastable fluid detectors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…Briefly, tensioned fluids are in state of metastability; their intermolecular bonds are weakened such that select stimuli types can "poke" holes into them to create transient bubbles that can rapidly (within µs) grow to states that are visible-audible to humans-depicted graphically in Figure 4. Amazingly, conventionally hard to detect sub-atomic neutral particles such as neutrons or ions (tell-tale signatures from U/Pu nuclear fission) can be now detected with unparalleled intrinsic efficiency [12] and spectroscopy even in ultra-low extreme radiation fields (per evidence presented later in this paper). Stimuli types may also include ordinary UV-IR photons.…”
Section: Introduction To Tensioned Metastable Fluid Detector (Tmfd) Smentioning
confidence: 86%
See 3 more Smart Citations
“…Briefly, tensioned fluids are in state of metastability; their intermolecular bonds are weakened such that select stimuli types can "poke" holes into them to create transient bubbles that can rapidly (within µs) grow to states that are visible-audible to humans-depicted graphically in Figure 4. Amazingly, conventionally hard to detect sub-atomic neutral particles such as neutrons or ions (tell-tale signatures from U/Pu nuclear fission) can be now detected with unparalleled intrinsic efficiency [12] and spectroscopy even in ultra-low extreme radiation fields (per evidence presented later in this paper). Stimuli types may also include ordinary UV-IR photons.…”
Section: Introduction To Tensioned Metastable Fluid Detector (Tmfd) Smentioning
confidence: 86%
“…Two distinct forms of hand portable, table-top systems: C (Centrifugal)-TMFDs and Acoustic (A)-TMFD hand-portable systems, weighing ≈2-3 kg, have been developed for high efficiency spectroscopic neutron-alpha-fission detection and are depicted schematically in Figure 5. Figure 6 demonstrates high efficiency fission spectrum neutron detection (≈100% of theoretical maximum) intrinsic efficiency which has been found to be ≈75 times higher (per unit volume) than for conventional systems, such as 12 kg, moderated BF3 detectors [11,12]. Shown (inset) are comparisons of neutron detection efficiency for TMFDs against the common state-of-art thermal and fast neutron detectors, including superheated drop detectors (SDDs).…”
Section: Detection Efficiency Of Tmfds Versus State-of-art Sensorsmentioning
confidence: 99%
See 2 more Smart Citations