1959
DOI: 10.1016/0006-291x(59)90020-8
|View full text |Cite
|
Sign up to set email alerts
|

Liquid scintillation counting of paper chromatograms

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0
1

Year Published

1962
1962
1983
1983

Publication Types

Select...
4
4
2

Relationship

0
10

Authors

Journals

citations
Cited by 124 publications
(9 citation statements)
references
References 1 publication
0
8
0
1
Order By: Relevance
“…The solvents were n-butanol : acetic acid: water (4:1:1 v/v); n-butanol saturated with 5% (w/v) aqueous trichloroacetic acid; and phenol:0.01 N hydrochloric acid (4:1 w/v) saturated with S02. The distribution of radioactivity on the papers was measured in a liquid scintillation spectrometer by the method of Wang & Jones (1959). In each case a single major peak corresponding in RF to authentic adrenaline or noradrenaline accounted for 95 to 99% of the radioactivity on the chromatograms.…”
Section: Methodsmentioning
confidence: 99%
“…The solvents were n-butanol : acetic acid: water (4:1:1 v/v); n-butanol saturated with 5% (w/v) aqueous trichloroacetic acid; and phenol:0.01 N hydrochloric acid (4:1 w/v) saturated with S02. The distribution of radioactivity on the papers was measured in a liquid scintillation spectrometer by the method of Wang & Jones (1959). In each case a single major peak corresponding in RF to authentic adrenaline or noradrenaline accounted for 95 to 99% of the radioactivity on the chromatograms.…”
Section: Methodsmentioning
confidence: 99%
“…1 filter paper. The chromatograms were developed with an n-butanol: acetic acid: water (4:1: 1 v/v) mixture as a descending system, and the distribution of radioactivity on the papers was measured in a liquid scintillation spectrometer by the method of Wang & Jones (1959). that Fraction I yielded a single peak of radioactivity corresponding in RF to authentic noradrenaline, and Fraction II yielded a smaller peak corresponding in R F to authentic normetanephrine together with a minor peak of noradrenaline.…”
Section: Perfusionsmentioning
confidence: 99%
“…Le volume de la réaction est de 10 ou 15 pl, la concentration en substrat d'au moins 0,0015 M; après addition de 10 ou 15 pl d'alcool absolu, les produits sont séparés par chromatographie sur papier (butanol sec: acide formique 85%: eau, 75:15:10) [17] sur une distance de 20 cm. La répartition de la radio activité est déterminée par comptage dans un scintillatene liquide [56].…”
unclassified