2015
DOI: 10.1142/s0217751x15300537
|View full text |Cite
|
Sign up to set email alerts
|

Liquid noble gases for dark matter searches: An updated survey

Abstract: An updated technical and methodological comparison of liquid noble gas experiments is presented with particular attention to the low energy physics application of double-phase noble gas detectors in direct Dark Matter investigations.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
25
0

Year Published

2016
2016
2018
2018

Publication Types

Select...
5
1
1

Relationship

3
4

Authors

Journals

citations
Cited by 19 publications
(26 citation statements)
references
References 154 publications
1
25
0
Order By: Relevance
“…The XENON100 experiment has released data for an exposure of 224.6 days, using a fiducial volume of just 34 kg of Xenon target mass [26]. See related discussions in literature about the detector response of such devices, in particular, to low energy recoils [27,28]. The technical performance of the apparata, confirmed also by similar experiments, has shown e.g.…”
Section: The Dark Matter Particles Detectionmentioning
confidence: 98%
See 1 more Smart Citation
“…The XENON100 experiment has released data for an exposure of 224.6 days, using a fiducial volume of just 34 kg of Xenon target mass [26]. See related discussions in literature about the detector response of such devices, in particular, to low energy recoils [27,28]. The technical performance of the apparata, confirmed also by similar experiments, has shown e.g.…”
Section: The Dark Matter Particles Detectionmentioning
confidence: 98%
“…[18,27,28,39,44]). However, often some critical points exist in their experimental aspects, as mentioned above, and the existing experimental and theoretical uncertainties are generally not considered in their presented single model dependent result; moreover, implications of the DAMA results are often presented in incorrect/partial/unupdated way.…”
Section: Ricap-2014mentioning
confidence: 99%
“…The XENON100 experiment has released data taken in the years 2011-2012 for an exposure of 224.6 days, using a fiducial volume of just 34 kg of Xenon target mass 35 . See related discussions in literature about the detector response of such devices, in particular, to low energy recoils 17,18,36 . The technical performance of the apparata, confirmed also by similar experiments, has shown, e.g.…”
Section: The Dark Matter Particles Detectionmentioning
confidence: 99%
“…Similar considerations, as above, hold about the robustness of these results. Moreover, such considerations become still more restrictive when considering the future plans of larger set-ups 17,18 . A positive hint for a signal of light DM candidates inducing just nuclear elastic scatterings has been also reported by the CoGeNT experiment 40,41 .…”
Section: The Dark Matter Particles Detectionmentioning
confidence: 99%
“…Some activities claim model-dependent exclusion under many largely arbitrary assumptions (see for example discussions in Ref. [10,11,15,[40][41][42]). Moreover, often some critical points exist in their experimental aspects, as mentioned above, and the existing experimental and theoretical uncertainties are generally not considered in their presented single model dependent result; moreover, implications of the DAMA results are often presented in incorrect/partial/unupdated way.…”
Section: Implications and Comparisonsmentioning
confidence: 99%