2013
DOI: 10.1016/j.chroma.2013.04.017
|View full text |Cite
|
Sign up to set email alerts
|

Liquid chromatography–mass spectrometry in metabolomics research: Mass analyzers in ultra high pressure liquid chromatography coupling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
106
0
9

Year Published

2014
2014
2018
2018

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 146 publications
(115 citation statements)
references
References 143 publications
0
106
0
9
Order By: Relevance
“…In such a scale-free network, highly inter-connected nodes tend to cluster together while sparsely connected ones are peripherally dispersed. Netcalc increases the percentage of m/z peaks, which can be assigned to a preliminary formula up to a 40e60% per dataset including isotope peaks 13 C. 6 The goal of this model is the visual and mathematical evaluation of organic molecular complexity in terms of elemental composition, an approach that permits explicitly defined relationships between different samples. 25 …”
Section: Network Analysismentioning
confidence: 99%
“…In such a scale-free network, highly inter-connected nodes tend to cluster together while sparsely connected ones are peripherally dispersed. Netcalc increases the percentage of m/z peaks, which can be assigned to a preliminary formula up to a 40e60% per dataset including isotope peaks 13 C. 6 The goal of this model is the visual and mathematical evaluation of organic molecular complexity in terms of elemental composition, an approach that permits explicitly defined relationships between different samples. 25 …”
Section: Network Analysismentioning
confidence: 99%
“…However, efficiency in the study of small molecules with m/z <300 by TOF analysis is often hindered by technical limitations such as lower mass accuracy, dynamic range, and multiplexing performance compared to an orbitrap, so the application of MetaboList with TOF instruments should be evaluated separately [8,[13][14][15].…”
Section: Ms/ms Ms E and Ms Allmentioning
confidence: 99%
“…16,[33][34][35][36] É uma técnica analítica que apresenta alta robustez, sensibilidade e seletividade, além de ser de fácil operação. 37 LC-MS é considerada uma técnica abrangente no que se refere à classe de compostos a serem analisadas, devido a grande variedade de fases estacionárias disponíveis, além dos diferentes modos de separação, como a eluição em fase reversa (fundamentalmente partição), com ou sem pareamento iônico, interação hidrofílica, e troca iônica.…”
Section: Figura 1 Esquema Resumido Do Fluxograma De Trabalho Envolviunclassified