LIQUID CHROMATOGRAPHIC MONITORING OF PHYTOECDYSTEROID PRODUCTION OF SERRATULA WOLFFII

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2001
2001
2012
2012

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 8 publications
0
9
0
Order By: Relevance
“…The 14a-hydroxy-7-en-6-one chromophore is responsible for ultraviolet (UV) absorption with max at 242 nm in methanol (Dinan 2001). To increase detection specificity for ECD analysis, HPLC combined with UV detection at 254 nm, instead of 242 nm, can be used (Bathori et al 2000).…”
Section: Structure and Types Of Phytoecdysteroidsmentioning
confidence: 99%
“…The 14a-hydroxy-7-en-6-one chromophore is responsible for ultraviolet (UV) absorption with max at 242 nm in methanol (Dinan 2001). To increase detection specificity for ECD analysis, HPLC combined with UV detection at 254 nm, instead of 242 nm, can be used (Bathori et al 2000).…”
Section: Structure and Types Of Phytoecdysteroidsmentioning
confidence: 99%
“…However, a simple clean-up on a polyamide micro-column retains the total amount of 20-hydroxyecdysone (and polypodine B) while the overwhelming majority of the interfering components are removed. LC requires clean-up using both Samplex (BioSeparation Technique, Budapest) and polyamide [11]. Without, and even with, the use Samplex C18, the LC separation of the plant sample exhibited a poorly resolved chromatogram.…”
Section: Discussionmentioning
confidence: 99%
“…Without, and even with, the use Samplex C18, the LC separation of the plant sample exhibited a poorly resolved chromatogram. It was found earlier [11], that fla- Pre-separation purification of the samples on polyamide was used for both TLC and MEKC. Both methods resulted in acceptable separation, although MEKC showed better resolution between polypodine B and 20-hydroxyecdysone.…”
Section: Discussionmentioning
confidence: 99%
“…To ensure the proper selectivity, these following mobile phases could be checked: [25]. The method used an automated spot application, developments using the adequate mobile phase, and the ultraviolet absorbance scanning densitometry of fluorescent-quenched spots of samples and that of the standards.…”
Section: Quantification Of Ecdysteroidsmentioning
confidence: 99%
“…Perfect specificity of a definite ecdysteroid determination was given by HPLC/MS or HPLC/MS/MS combination [20][21][22]. HPLC/RIA 10 -9 g [23] Spectrophotometry 10 -6 g [24] TLC 5x10 -5 g [25] groups of ecdysteroids, thereby any hydroxylated compound gave the same reaction), the HPLC/fluorescence detection did not become a popular assay [18][19].…”
Section: Quantification Of Ecdysteroidsmentioning
confidence: 99%