1991
DOI: 10.1002/jsfa.2740560110
|View full text |Cite
|
Sign up to set email alerts
|

Liquid chromatographic determination of free and total sulphites in fresh sausages

Abstract: A B S T R A C T The present work describes a method for the determination of free and total

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
17
0

Year Published

1993
1993
2020
2020

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 13 publications
(18 citation statements)
references
References 12 publications
(16 reference statements)
1
17
0
Order By: Relevance
“…In particular some of the samples contained 8-16 times the maximum level. Very similar results were obtained previously in a survey carried out on fresh sausages (Paino Campa et al, 1991). This shows that the amounts of sulphite added are sometimes excessively high.…”
Section: Contents In Fresh and Fried Burgerssupporting
confidence: 90%
See 2 more Smart Citations
“…In particular some of the samples contained 8-16 times the maximum level. Very similar results were obtained previously in a survey carried out on fresh sausages (Paino Campa et al, 1991). This shows that the amounts of sulphite added are sometimes excessively high.…”
Section: Contents In Fresh and Fried Burgerssupporting
confidence: 90%
“…The method involved the extraction of free and total sulphite with a suitable solvent followed by HPLC determination with electrochemical detection as described previously (Paino Campa et al 1991). For comparative purposes the optimized Moriier-Williams method was used (FDA 1986).…”
Section: Methods Of Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…However, these two techniques suffer some analytical uncertainties/weaknesses. Alternatively, Armentia-Alvarez et al (1993) applied another chromatographic method, proposed by Pa ıno-Campa et al (1991), for analysis of fresh and cooked burgers. Regarding the enzymatic method, it is well known that ascorbic acid represents an important interference with this enzymatic reaction (Beutler, 1984), and considering that this compound is widely used in fresh meat preparations (Iammarino & Di Taranto, 2013a), this is an important limitation of this method.…”
Section: Sulphiting Agentsmentioning
confidence: 99%
“…This method was characterised by high specificity, good sensitivity (LOQ = 8.2 mg kg À1 of SO 2 ), precision (relative standard deviation under repeatable conditions <6.0) and mean recovery (88.6%). Alternatively, Armentia-Alvarez et al (1993) applied another chromatographic method, proposed by Pa ıno- Campa et al (1991), for analysis of fresh and cooked burgers. This method was based on sulphite extraction by a solution composed of sulphuric acid and glycerol, a chromatographic separation accomplished using an anion exclusion column and final detection through an electrochemical detector equipped with a glassy carbon electrode and a Ag/AgCl reference electrode.…”
Section: Sulphiting Agentsmentioning
confidence: 99%