2011
DOI: 10.1016/j.chroma.2011.07.002
|View full text |Cite
|
Sign up to set email alerts
|

Lipophilicity assessment of basic drugs (logPo/w determination) by a chromatographic method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
15
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(15 citation statements)
references
References 35 publications
0
15
0
Order By: Relevance
“…More recently, a study used CNS drugs and tested them in a mouse model where genes that encode the P-gp efflux pumps have been knocked out. This study demonstrated that out of 34 CNS drugs, only 7 showed no evidence of efflux using -1 to 5.9 --PSA-dependent [55] Bioavailability ---2 to 3 [56] 0 to 3 -- [42] --1 to 3 [58] < 3 --Ionization-dependent [11] Distribution " better --Ionization-dependent [11] CNS Penetration " better --MW-dependent [11,71] > 2 --…”
Section: Cns Penetrationmentioning
confidence: 90%
See 2 more Smart Citations
“…More recently, a study used CNS drugs and tested them in a mouse model where genes that encode the P-gp efflux pumps have been knocked out. This study demonstrated that out of 34 CNS drugs, only 7 showed no evidence of efflux using -1 to 5.9 --PSA-dependent [55] Bioavailability ---2 to 3 [56] 0 to 3 -- [42] --1 to 3 [58] < 3 --Ionization-dependent [11] Distribution " better --Ionization-dependent [11] CNS Penetration " better --MW-dependent [11,71] > 2 --…”
Section: Cns Penetrationmentioning
confidence: 90%
“…The chromatographic hydrophobicity index (CHI) developed by Valko et al can be used as an independent measure of hydrophobicity [44] and offers a simple way to evaluate the log P of a drug [45]. In fact, the need to correct chromatographic measurements with the hydrogen bond acidity to get reliable log P values has been demonstrated recently [42,46]. This is a remarkable feature since pure chromatographic methods only offer good estimations of log P for compounds without significant hydrogen bond acidity.…”
Section: Measuring Lipophilicitymentioning
confidence: 97%
See 1 more Smart Citation
“…On the other hand, the negative sign of the coefficient at the analyte polarity descriptor l 2 proves stronger attractions between the analyte and the polar eluent molecules than between the same analyte molecule and the nonpolar hydrocarbon ligand of the stationary phase. [1,14] The value (negative) of the coefficient k 2 at dipole moment square in Table 6, regarding the methanol-modified systems, is largest for the Unison UK-C18 column and smallest for the Zorbax SB-C18 column. In the case of acetonitrile as the organic modifier, the largest is the respective coefficient (negative) for the MICRA NPS ODS I column and Unison UK-C18 column and the smallest for the Zorbax SB-C18 column.…”
Section: Resultsmentioning
confidence: 96%
“…The analysis of the dis- 46 solution mechanisms and the prediction of API dissolution profiles 47 from intrinsic dissolution as well as from actual tablets are chal- 48 lenging topics in pharmaceutical development. In the last decades, 49 several empirical, semi-empirical and mechanistic mathematical 50 models have been proposed to describe the API dissolution profiles 51 from a variety of solid pharmaceutical dosage forms, e.g. matrix 52 systems [1][2][3], erodible tablets [4,5], microspheres [6], hydrogels 53 [7], powders [8] and immediate release tablets [9][10][11][12].…”
mentioning
confidence: 99%