Lipemia and bilirubin influences for twenty-four biochemical parameters measurement

Abstract: L'étude de l'influence de la lipémie et de l'ictère a été réalisée expérimentalement pour 24 paramètres de biochimie sur l'automate Cobas 6000 Roche. Des surcharges en Intralipid ® ou en ditaurate de bilirubine ont été effectuées sur différents pools plasmatiques. La limite de 10 % a été choisie pour définir une interférence sur la mesure. Les paramètres étudiés ont été classés en différentes catégories selon que leur mesure soit impactée ou non. La connaissance de ces données permet au biologiste d'adapter se… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
7
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(12 citation statements)
references
References 23 publications
4
7
1
Order By: Relevance
“…Statistically and clinically significant negative interference was detected for alanine aminotransferase (ALT) and aspartate aminotransferase (AST), consistent with previous studies ( 14 , 31 , 32 ). When lipemia index values were 159 and 174 for NULM and IVLE, respectively, the negative interference amount exceeded the 10% limit, conforming to the manufacturer’s declaration (Supplementary table 2).…”
Section: Discussionsupporting
confidence: 90%
See 1 more Smart Citation
“…Statistically and clinically significant negative interference was detected for alanine aminotransferase (ALT) and aspartate aminotransferase (AST), consistent with previous studies ( 14 , 31 , 32 ). When lipemia index values were 159 and 174 for NULM and IVLE, respectively, the negative interference amount exceeded the 10% limit, conforming to the manufacturer’s declaration (Supplementary table 2).…”
Section: Discussionsupporting
confidence: 90%
“…Interference evaluations were made for biochemistry parameters using IVLE on the Roche Cobas 6000 analyzer and these data were published before ( 31 , 32 ). Our results were evaluated by comparison with these studies and, where available, with test-based studies.…”
Section: Discussionmentioning
confidence: 99%
“…As these two parameters are available, it is possible to estimate the true analyte level. However, Ali et al 18 show that there are two levels of interference for PROT, tested at 30 and 74 g/L, which are outside our studied range. For TG, due to the nature of the relationship, with I ict and % of interference, two equations are needed.…”
Section: Resultscontrasting
confidence: 52%
“…Spurious hyperphosphatemia was documented in 6 patients [21] with severe hyperbilirubinemia (>330 µmol/L). This tendency was confirmed in 4 reports examining the interference from bilirubin on the determination of this ion [22][23][24][25].…”
Section: • Hyperbilirubinemiamentioning