Encyclopedia of Electrochemistry 2003
DOI: 10.1002/9783527610426.bard030201
|View full text |Cite
|
Sign up to set email alerts
|

Linear Sweep and Cyclic Voltammetry

Abstract: The sections in this article are Introduction Historical Background Potential Scan Voltammetries—Definitions Scope of the Chapter Theory of Potential Scan Voltammetries General Reversible Electron Transfer Kinetics of Electron Tran… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
3
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 79 publications
1
3
0
Order By: Relevance
“…The calibration demonstrates that current density values of anodic and cathodic peaks have a linear correlation with the square roots of the scan rate (ν 1/2 ) variation, with correlation coefficient values (R 2 ) of 0.9996 and 0.9871, respectively. This correlation infers the diffusion-controlled mechanism of the electrochemical reaction on the surface of MWCNT/AgNP-SPCE [54].…”
Section: Optimization Of Various Parameters In the Fabrication Of Mwc...supporting
confidence: 60%
“…The calibration demonstrates that current density values of anodic and cathodic peaks have a linear correlation with the square roots of the scan rate (ν 1/2 ) variation, with correlation coefficient values (R 2 ) of 0.9996 and 0.9871, respectively. This correlation infers the diffusion-controlled mechanism of the electrochemical reaction on the surface of MWCNT/AgNP-SPCE [54].…”
Section: Optimization Of Various Parameters In the Fabrication Of Mwc...supporting
confidence: 60%
“…Figure 9B points out the linear relation between the square root of the potential scan rate and the peak current with the linear equation, as seen in Equations ( 1) and ( 2) for anodic and cathodic peaks, respectively. The linearity indicates that the diffusion-controlled reaction dominates dopamine's electrochemical detection [43].…”
Section: Effect Of the Potential Scan Rate Variationmentioning
confidence: 98%
“…Using electrophoretic technique, the film was coupled onto the surface of ITO coated glass plate. The linear sweep voltammetry was used to carry out response studies [49]. In 2010, Dhand et al fabricated a working bioelectrode represented as Lipase-GDH/PANI-SWCNT-TB/ITO, which could detect tributyrin in the concentration range of 50-400 mg/dL À1 in a short response time of 12 s. The electrode displayed high sensitivity of 4.28 Â 10 À4 mA mg/dL and storage stability of 91 days [50].…”
Section: Tg Biosensors Based On Conducting Polymermentioning
confidence: 99%