2016
DOI: 10.1093/mnras/stw2545
|View full text |Cite
|
Sign up to set email alerts
|

Linear spectropolarimetry of polarimetric standard stars with VLT/FORS2

Abstract: We reduced ESO's archival linear spectropolarimetry data (4000-9000Å) of 6 highly polarized and 8 unpolarized standard stars observed between 2010 and 2016, for a total of 70 epochs, with the FOcal Reducer and low dispersion Spectrograph (FORS2) mounted at the Very Large Telescope. We provide very accurate standard stars polarization measurements as a function of wavelength, and test the performance of the spectropolarimetric mode (PMOS) of FORS2. We used the unpolarized stars to test the time stability of the… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

4
50
0
16

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 47 publications
(72 citation statements)
references
References 11 publications
(33 reference statements)
4
50
0
16
Order By: Relevance
“…The halfwave retarder plate was positioned at four angles of 0 • , 22.5 • , 45 • , and 67.5 • per sequence. The ordinary and extraordinary beams were extracted using standard procedures in IRAF (as described in Cikota et al 2017a). Wavelength calibration was achieved using He-Ne-Ar arc lamp exposures.…”
Section: Instruments and Observationsmentioning
confidence: 99%
“…The halfwave retarder plate was positioned at four angles of 0 • , 22.5 • , 45 • , and 67.5 • per sequence. The ordinary and extraordinary beams were extracted using standard procedures in IRAF (as described in Cikota et al 2017a). Wavelength calibration was achieved using He-Ne-Ar arc lamp exposures.…”
Section: Instruments and Observationsmentioning
confidence: 99%
“…where λ must be expressed in Å. Cikota et al (2017) derived Eqs. (8) from observations taken with the instrument position angle χ set to zero (i.e.…”
Section: Correction For the Chromatism (Wavelength Dependence) Of Thementioning
confidence: 99%
“…Numerical simulations performed by Cikota et al (2017, presentation at the ESO Calibration Workshop) suggested that this short-timescale variability could be linked to an inaccurate setting of the retarder waveplate.…”
Section: Inconsistencies Between Consecutive Observationsmentioning
confidence: 99%
See 1 more Smart Citation
“…Skalidis et al (2018); (3)Cikota et al (2017); (4)Turnshek et al (1990); (5)Berdyugin & Teerikorpi (2002) …”
mentioning
confidence: 99%