1998
DOI: 10.1016/s0021-8502(97)00292-9
|View full text |Cite
|
Sign up to set email alerts
|

Linear Raman spectroscopy on aqueous aerosols: influence of nonlinear effects on detection limits

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
16
0

Year Published

1999
1999
2011
2011

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(17 citation statements)
references
References 70 publications
1
16
0
Order By: Relevance
“…Unfortunately, the models for the calculation of the SRS threshold respectively, the gain enhancement in droplets given by Schweiger, 6 Lin and Campillo 11 and Vehring 12 does not contain any consideration of the excitation pulse form or duration. However, different experimental research was done for the determination of the photon lifetime in droplets.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Unfortunately, the models for the calculation of the SRS threshold respectively, the gain enhancement in droplets given by Schweiger, 6 Lin and Campillo 11 and Vehring 12 does not contain any consideration of the excitation pulse form or duration. However, different experimental research was done for the determination of the photon lifetime in droplets.…”
Section: Resultsmentioning
confidence: 99%
“…Additionally, the seeding of the laser and thereby, the avoidance of temporal spikes in the origin laser pulse can potentially increase the SRS threshold. The droplet cavity quality can be reduced by the decrease of the ratio of the refraction index of the liquid and the environment 9 or by absorption of the excitation light in the droplets by a dye 12,14 , by induced or random imperfections of the droplet surface. Other recommendations that can be found in the literature are, for example, the use of broadband laser sources or ultra short (picosecond) laser excitation.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Stimulated Raman scattering has been used to characterize aqueous aerosols by linear Raman spectroscopy. 144 Scanning near-IR Raman microscopy has been successfully used to map aerosol particulate deposits on the stages of an Anderson cascade impactor (ACI), as shown in Figure 9, from a combination pressurized MDI (pMDI), Ventide. 145 ACI is the standard in vitro model of aerosol deposition in the lungs.…”
Section: E8mentioning
confidence: 99%
“…Laboratory measurements of Raman spectra from levitated microspheres have been performed by numerous investigators [Vehring et al, 1995Schweiger, 1991;Buehler et al, 1991;Bazile and Stepowski, 1994;Vehring, 1998]. These experiments have been performed over various size parameter ranges, where size parameter is defined as the circumference of the sphere divided by the input wavelength.…”
Section: Theory: Raman Scattering From Spheresmentioning
confidence: 99%