2021
DOI: 10.1016/j.jqsrt.2020.107453
|View full text |Cite
|
Sign up to set email alerts
|

Line parameters of the 4-0 band of carbon monoxide by high sensitivity cavity ring down spectroscopy near 1.2 µm

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 36 publications
0
4
0
Order By: Relevance
“…The recording procedure is similar to that adopted to measure D 2 transitions in the (2-0) band 26,29,30 except that an external cavity diode laser (ECDL) is used as a light source instead of distributed-feedback (DFB) laser diodes. The ECDL (Toptica fiber-connected DL pro, 1200 nm) was tuned to record small spectral intervals around the Q1–Q4, S0, and S1 transitions spanning the 7970–8605 cm −1 region.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The recording procedure is similar to that adopted to measure D 2 transitions in the (2-0) band 26,29,30 except that an external cavity diode laser (ECDL) is used as a light source instead of distributed-feedback (DFB) laser diodes. The ECDL (Toptica fiber-connected DL pro, 1200 nm) was tuned to record small spectral intervals around the Q1–Q4, S0, and S1 transitions spanning the 7970–8605 cm −1 region.…”
Section: Methodsmentioning
confidence: 99%
“…Following ref. 27 and 29, a self-referenced frequency comb (Model FC 1500-250 WG from Menlo Systems) was used for the frequency calibration of the spectra. The frequency attached to each ring-down event is determined from (i) the frequency measurement of the beat note between a fraction of the ECDL light and a tooth of the frequency comb and (ii) the tooth number deduced from the frequency value provided by a commercial Fizeau-type wavemeter (HighFinesse WSU7-IR, 5 MHz resolution, 20 MHz accuracy over 10 hours).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…As further checks of the accuracy of the frequency calibration of our spectra, we consider a few individual lines with line positions accurately measured in the literature. We first compared the water position values to those measured in low pressure CO spectra where water was present as an impurity [34]. The CO spectra were recorded by comb-reference CRDS with the same setup used in this work.…”
mentioning