Line-Field Optical Coherence Tomography as a tool for In vitro characterization of corneal biomechanics under physiological pressures

Abstract: There has been a lot of interest in accurately characterising corneal biomechanical properties under intraocular pressure (IOP) to help better understand ocular pathologies that are associated with elevated IOP. This study investigates the novel use of Line-Field Optical Coherence Tomography (LF-OCT) as an elastographic tool for accurately measuring mechanical properties of porcine corneas based on volumetric deformation following varying IOPs. A custom-built LF-OCT was used to measure geometrical and corneal … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
1

Year Published

2020
2020
2021
2021

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 75 publications
0
3
1
Order By: Relevance
“…Elastic modulus values of porcine corneas, reported in previous studies [52,53], is less than those measured by AFM (nano-scale). E of control corneas (whole thickness) tested by nanoindentation with a 100 µm flat punch [52] and inflation testing [53] were in the range of 40 to 700 kPa depending on testing conditions such as internal pressure and hydration. However, E measured on corneal sections (5 µm thick) in this study were in the range of 2 to 2.45 GPa.…”
Section: Corneal Degradation With Collagenasecontrasting
confidence: 58%
“…Elastic modulus values of porcine corneas, reported in previous studies [52,53], is less than those measured by AFM (nano-scale). E of control corneas (whole thickness) tested by nanoindentation with a 100 µm flat punch [52] and inflation testing [53] were in the range of 40 to 700 kPa depending on testing conditions such as internal pressure and hydration. However, E measured on corneal sections (5 µm thick) in this study were in the range of 2 to 2.45 GPa.…”
Section: Corneal Degradation With Collagenasecontrasting
confidence: 58%
“…Experimental validation of our technique was done using a lab-made par-65 allel SD-OCT [22] instrument, also known as line-field OCT [23,24] as shown the null of the J 0 curve is clearly defined.…”
Section: Experimental Results and Conclusion 64mentioning
confidence: 99%
“…In conclusion, we have demonstrated a new technique for removal of autocorrelation which can work with arbitrarily strong and arbitrarily located autocorrelation artifacts. Our technique is specially suited for parallel or line-field FD-OCT devices[22,6,23,24] using spectrometers with 2-D sensors (cameras) which result in single-shot B-scans.Funding This work was not funded by any grant. Our department had infrastructure funding from the Department of Science and Technology, Government of India (DST) -DST FIST 2012-2017 SR/FST/PSI-172/2012.…”
mentioning
confidence: 99%
“…Instead, we explore a way to use the two-dimensional camera sensor in a parallel spectrometer design. The schematic of a parallel FD-OCT [14,15] setup, also known as line-field OCT [16,17] is shown in Figure 6. Such a configuration captures data for a complete B-scan in a single frame captured by the camera.…”
Section: Motivationmentioning
confidence: 99%