Limitations of ultrasound guided follicular aspiration for analysis of ovarian follicular fluid in dairy cattle

Abstract: The aim of this study was to evaluate the applicability of ovum pick-up equipment for follicular fluid collection from various follicular structures (experiment 1) and for recovery of follicular fluid for acid-base balance analysis (experiment 2). An ultrasound scanner equipped with a 5-MHz convex transducer was used for transvaginal ultrasound-guided follicular aspiration. A 17-gauge, 60-cm aspiration needle was connected with a shortened aspiration line. The fluid was aspirated manually into a 2 ml plastic s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
8
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 28 publications
1
8
0
Order By: Relevance
“…The values of estimated parameters in samples collected using the ABB set and the OPUe under anaerobic conditions were similar. With these results we have confirmed our previous findings (Cech et al 2011) that O 2 from air present in the aspiration needle and line passes into the sample, and that CO 2 escapes from the sample into the air present in the aspiration needle and line according to a concentration gradient. As a consequence of lower pCO 2 we found higher pH values.…”
Section: Discussionsupporting
confidence: 80%
See 3 more Smart Citations
“…The values of estimated parameters in samples collected using the ABB set and the OPUe under anaerobic conditions were similar. With these results we have confirmed our previous findings (Cech et al 2011) that O 2 from air present in the aspiration needle and line passes into the sample, and that CO 2 escapes from the sample into the air present in the aspiration needle and line according to a concentration gradient. As a consequence of lower pCO 2 we found higher pH values.…”
Section: Discussionsupporting
confidence: 80%
“…Therefore, after insertion of the holder into the vagina it is present immediately in front of the ovary. Aspirated fluid does not have to travel as long a distance, as is the case for the older OPUe device, and thus, is not contaminated by air present in the aspiration system, as we demonstrated in a previous study (Cech et al 2011). We used our new ABB set for the aspiration of the first sample from each sequence, because we needed two repeated aspirations of each cyst; disposable 22G needles used in the ABB set cause lower mechanical trauma to the aspirated structure than the 17G needle used in the modified OPUe.…”
Section: Discussionmentioning
confidence: 50%
See 2 more Smart Citations
“…Follicular fluid for E2, P4, insulin-like growth factor 1 (IGF1), insulin, cholesterol, and NEFA determination was aspirated from preovulatory follicles on D42 (oestrus 2) in 10 cows (5 experimental and 5 control cows). Dominant follicles 15-20 mm in diameter were aspirated using a transvaginal ultrasound-guided follicular aspiration (TVFA) according to Cech et al (2011). The follicular fluid was aspirated manually into a 2 ml plastic syringe until the dominant follicle was aspirated completely.…”
Section: Methodsmentioning
confidence: 99%