2018 IEEE 2nd International Conference on Dielectrics (ICD) 2018
DOI: 10.1109/icd.2018.8514634
|View full text |Cite
|
Sign up to set email alerts
|

Limitation of test sample arrangements according to IEC 60243-1: Electrical strength of insulating materials - Test methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2019
2019
2019
2019

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Electric breakdown strength is an important property of insulation material for high voltage applications and test procedures to determine the short-term electric strength, as described in ASTM D149 and IEC 60243 [1,2]. In spite of the standards, reliable and meaningful conclusions can be very difficult to draw from the test results [3,4]. Test results are to a great extent dependent on a variety of different test conditions, but one of the main challenges is still to reduce the influence at the triple point between electrodes, test object, and the immersion fluid [4][5][6].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Electric breakdown strength is an important property of insulation material for high voltage applications and test procedures to determine the short-term electric strength, as described in ASTM D149 and IEC 60243 [1,2]. In spite of the standards, reliable and meaningful conclusions can be very difficult to draw from the test results [3,4]. Test results are to a great extent dependent on a variety of different test conditions, but one of the main challenges is still to reduce the influence at the triple point between electrodes, test object, and the immersion fluid [4][5][6].…”
Section: Introductionmentioning
confidence: 99%
“…In spite of the standards, reliable and meaningful conclusions can be very difficult to draw from the test results [3,4]. Test results are to a great extent dependent on a variety of different test conditions, but one of the main challenges is still to reduce the influence at the triple point between electrodes, test object, and the immersion fluid [4][5][6]. Often the breakdowns are triggered by surface discharges at this triple point giving breakdown channels located close to the electrode edges or outside the active electrode area.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation