2004
DOI: 10.1016/s0038-092x(04)00070-2
|View full text |Cite
|
Sign up to set email alerts
|

Lightswitch-2002: a model for manual and automated control of electric lighting and blinds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
150
0
1

Year Published

2007
2007
2019
2019

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 89 publications
(151 citation statements)
references
References 0 publications
0
150
0
1
Order By: Relevance
“…Different illuminance thresholds are associated to the different building typologies and kind of uses of spaces in a building. In a typical office use, the European standard EN 12464-1 [77] and most authors suggest a reference value of 500 lx evaluated on the work-plane [78][79][80][81]; while others consider sufficient 425 lx [6] or even 300 lx [82].…”
Section: Illuminancementioning
confidence: 99%
“…Different illuminance thresholds are associated to the different building typologies and kind of uses of spaces in a building. In a typical office use, the European standard EN 12464-1 [77] and most authors suggest a reference value of 500 lx evaluated on the work-plane [78][79][80][81]; while others consider sufficient 425 lx [6] or even 300 lx [82].…”
Section: Illuminancementioning
confidence: 99%
“…Light levels were calculated in the vertical plane to imitate light hitting the cornea of the eye and were simulated for two locations (variable 6 in Table 1; the two points are shown in plan in Figure 1c) to model an occupant walking back and forth in the space. [48] -defined as the percentage of occupation time a given illuminance threshold can be achieved by daylighting alone -was chosen as the reference metric for analyzing light penetration and distribution patterns over time and space because it is by definition based on a minimal illuminance threshold and because it can provide a synthetic (single number expressed as a percentage) evaluation of annual, climate-based daylight performance that can account for blind control [49].…”
Section: Design Of Experimental Setupmentioning
confidence: 99%
“…One caveat related to this study is that the use of dynamic shading systems has not been addressed thus far even though methods to model the use of movable shading systems have been proposed in the past [Reinhart 2004;Haldi & Robinson 2010;O'Brien et al 2013]. The reason for this shortcoming is that it is doubtful whether students and or in fact any non-expert visiting a space for a single time could possibly predict the implications of a shading device and control situation over a whole year.…”
Section: Open Questionsmentioning
confidence: 99%