2016
DOI: 10.1049/iet-smt.2015.0199
|View full text |Cite
|
Sign up to set email alerts
|

Lightning back flashover tripping patterns on a 275/132 kV quadruple circuit transmission line in Malaysia

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 14 publications
0
8
0
Order By: Relevance
“…The nature of the voltage stresses that a transmission line system had experience power frequency, lightning, and switching overvoltages [17,[25][26][27][28][29][30][31]. Both transient an power frequency overvoltages stresses appear in all shapes and with different amplitude Each type of transient and power frequency overvoltages may occur during most types o meteorological conditions, leading to the flashover strength differently [32].…”
Section: Voltage Uprating For the Typical Tower Of 132 Kv Transmission Line Processes And Itsmentioning
confidence: 99%
See 1 more Smart Citation
“…The nature of the voltage stresses that a transmission line system had experience power frequency, lightning, and switching overvoltages [17,[25][26][27][28][29][30][31]. Both transient an power frequency overvoltages stresses appear in all shapes and with different amplitude Each type of transient and power frequency overvoltages may occur during most types o meteorological conditions, leading to the flashover strength differently [32].…”
Section: Voltage Uprating For the Typical Tower Of 132 Kv Transmission Line Processes And Itsmentioning
confidence: 99%
“…The nature of the voltage stresses that a transmission line system had experienced power frequency, lightning, and switching overvoltages [17,[25][26][27][28][29][30][31]. Both transient and power frequency overvoltages stresses appear in all shapes and with different amplitudes.…”
Section: Voltage Uprating For the Typical Tower Of 132 Kv Transmission Line Processes And Its Analysesmentioning
confidence: 99%
“…The nature of the voltage stresses that a transmission line system had experienced power frequency, lightning, and switching overvoltages [67][68][69][70][71][72][73][74]. Both transient and power frequency voltage stresses appear in all shapes and with different amplitudes.…”
Section: Electrical Clearances Requirementmentioning
confidence: 99%
“…Multiconductor transmission lines (MTLs) are widely used in electrical and electronic engineering as the significant transmission path of energy and information [1][2][3][4], but they are vulnerable to external electromagnetic (EM) interferences [5], i.e. emissions from lighting EM pulse [6][7][8], high-power radars, high-altitude EM pulse (HEMP) etc. HEMP is a complex multi-pulse, and its earlytime (E1) component is characterised by large radiation scope, intense field strength, and wide-frequency spectrum [9].…”
Section: Introductionmentioning
confidence: 99%