2022
DOI: 10.33963/kp.a2022.0181
|View full text |Cite
|
Sign up to set email alerts
|

Lightning 12: A new player in the field of pulmonary percutaneous mechanical thrombectomy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 4 publications
0
3
0
Order By: Relevance
“…Recently, a new generation of Lightning 12F system (Penumbra Inc, Alameda, CA, USA) was introduced that includes new innovative mechanisms to prevent blood loss, efficiently regulate aspiration and enable aspiration of larger clots. 12 , 34 What is more, the next-generation highly torqueable Lightning Flash 16 system (Penumbra Inc, Alameda, CA, USA) with dual clot detection algorithms and no necessity for separator use has just been released in the USA. 35 The results of the ongoing STRIKE-PE study will show whether Lightning technology ultimately improves short- and long-term clinical outcomes.…”
Section: Discussionmentioning
confidence: 99%
“…Recently, a new generation of Lightning 12F system (Penumbra Inc, Alameda, CA, USA) was introduced that includes new innovative mechanisms to prevent blood loss, efficiently regulate aspiration and enable aspiration of larger clots. 12 , 34 What is more, the next-generation highly torqueable Lightning Flash 16 system (Penumbra Inc, Alameda, CA, USA) with dual clot detection algorithms and no necessity for separator use has just been released in the USA. 35 The results of the ongoing STRIKE-PE study will show whether Lightning technology ultimately improves short- and long-term clinical outcomes.…”
Section: Discussionmentioning
confidence: 99%
“…Recently, a new Lightning 12, intelligent computer-assisted vacuum aspiration system (Penumbra, Alameda, CA, US) has been introduced, which is thought to more efficiently regulate aspiration, and reduce blood loss in comparison to the previous generation device (Indigo CAT8) [4][5][6]. This study aims to evaluate the outcomes of the Lightning 12 aspiration system.…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, the 12F catheter's flexibility advantageously improves maneuvers within tortuous vessels and enlarged right heart ventricles. A larger diameter, improved catheter design, and an intelligent control unit allow for the more adequate removal of thrombi from both pulmonary arteries without increasing periprocedural blood loss compared to the previous generation of the device (Indigo CAT8 device) [5,[9][10][11]. Using larger-bore catheters and sheaths seems feasible and effective.…”
mentioning
confidence: 99%
“…It may favor a more aggressive approach, including faster utilization of catheter-directed therapies despite the fact the patient is at "intermediate" risk and looks hemodynamically stable [3]. In this context, contemporary large-bore aspiration catheters seem to be a breakthrough in the treatment of patients with PE [4].…”
mentioning
confidence: 99%