2016
DOI: 10.1016/j.solener.2015.12.053
|View full text |Cite
|
Sign up to set email alerts
|

Lighting control systems in individual offices rooms at high latitude: Measurements of electricity savings and occupants’ satisfaction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
22
1
4

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
2
1

Relationship

2
7

Authors

Journals

citations
Cited by 61 publications
(31 citation statements)
references
References 26 publications
1
22
1
4
Order By: Relevance
“…The occupancy control system could automatically turn on/off the electric lighting when the presence is detected (presence switches), or only switch off a manually turned on system when any movement is recognized (absence switches). The differences in savings between these two approaches could be high, especially in individual or small offices, as shown by Gentile et al (2012). These authors showed that using a presence (on/off) control system in small offices would yield higher energy use for lighting than a simple manual switch at the door with an absence detector (switch off), confirming results from previous research (Voss et al, 2006).…”
Section: Occupancy Controlssupporting
confidence: 76%
See 1 more Smart Citation
“…The occupancy control system could automatically turn on/off the electric lighting when the presence is detected (presence switches), or only switch off a manually turned on system when any movement is recognized (absence switches). The differences in savings between these two approaches could be high, especially in individual or small offices, as shown by Gentile et al (2012). These authors showed that using a presence (on/off) control system in small offices would yield higher energy use for lighting than a simple manual switch at the door with an absence detector (switch off), confirming results from previous research (Voss et al, 2006).…”
Section: Occupancy Controlssupporting
confidence: 76%
“…Lee and Selkowitz, 2006;Gentile et al, 2012). The practical difficulties regard mainly the performance of the photo sensor (Ehrlich et al, 2002), since the whole system is based on its reading of the light environment.…”
Section: Daylight-linked Control Systemsmentioning
confidence: 99%
“…The use of natural daylight in buildings significantly reduces the electric energy consumption by minimizing the use of artificial lighting during the day [8]. Previous research has shown that daylight utilization (replacement of electric light by daylight) can reduce the use of electric lighting by 50%-80% in office buildings [14]. Malaysian Minister of Energy, Communication and Multimedia, Tan Sri Datuk Leo Moggie said that one of the ways to save energy was through the efficient use of energy in building by the use of extensive day-lighting techniques that would reduce the amount electricity produced by lighting fixtures [15].…”
Section: The Issuementioning
confidence: 99%
“…A system of illuminance sensors and electricity meters for the electric lights was installed to record the indoor and outdoor illuminance levels and the electricity consumption for the lighting system [23]. The data was collected by a logger, which was located in a service room adjoining the pig houses (Fig.…”
Section: Measuring Systemmentioning
confidence: 99%