1986
DOI: 10.1016/0032-3861(86)90133-3
|View full text |Cite
|
Sign up to set email alerts
|

Light scattering study of stereocomplex behaviour in solutions of poly(methyl methacrylate)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

1
2
0

Year Published

1988
1988
2018
2018

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 33 publications
1
2
0
Order By: Relevance
“…The corresponding dn/dc value for homo-PMMA in acetonitrile is obtained from literature as 0.140 cm 3 /g. 40 The dn/dc values presented are the same as this literature value, and hence the measured apparent molecular weight is close to the true molecular weight.…”
Section: Methodssupporting
confidence: 62%
See 1 more Smart Citation
“…The corresponding dn/dc value for homo-PMMA in acetonitrile is obtained from literature as 0.140 cm 3 /g. 40 The dn/dc values presented are the same as this literature value, and hence the measured apparent molecular weight is close to the true molecular weight.…”
Section: Methodssupporting
confidence: 62%
“…Due to the chemical heterogeneity of block copolymers, the weight-average molecular weight determined in static light scattering measurements is an apparent molecular weight. The corresponding d n /d c value for homo-PMMA in acetonitrile is obtained from literature as 0.140 cm 3 /g . The d n /d c values presented are the same as this literature value, and hence the measured apparent molecular weight is close to the true molecular weight.…”
Section: Methodsmentioning
confidence: 54%
“…NMR spectra were recorded with a Bruker Avance II 300: 1 H (300.13MHz), 13 C (74.48 MHz), 19 F (282.40 Mhz) at 298 K in CDCl3. Chemical shifts are expressed in parts per million with residual solvent signals as internal reference ( 1 H and 13 C) 16 or with an external reference (CF3Cl for 19 F). Melting points were determined using a Reichert microscope apparatus and are uncorrected.…”
Section: Methodsmentioning
confidence: 99%
“…Synthetic polymers can be heterogeneous with respect to molar mass, chemical composition, chain architecture, functionality, and tacticity. It has been shown that the tacticity influences the physical properties of poly(methyl methacrylate) (PMMA). Various techniques have been used to study stereoregular PMMAs. Stereoregular PMMAs have also been explored as stationary phases in chromatography . The molecular structure of isotactic (mmm), syndiotactic (rrr), and atactic (mrr) PMMA are presented in Figure .…”
mentioning