Light microscopy evaluation of polyurethane vascular grafts porosity by Sudan Black B staining

Abstract: SummaryIn small-diameter vascular grafts, the porosity of the internal surface plays an important role because it affects initial thrombus deposition and therefore the graft's patency. As well as many other studies reported in the literature we have carried out a study of the relationship between porosity and the manufacturing parameters of polyurethane (PU) grafts by standard scanning electron microscopy (SEM) analysis. However, SEM was not completely satisfactory for evaluating the 'sponge-like' uptake of wa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2006
2006
2018
2018

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 12 publications
0
5
0
Order By: Relevance
“…Graft microgeometry was examined by Sudan Black staining with a procedure previously described . Briefly, graft samples were dipped in a staining solution (0.12% w/v in absolute ethanol) for 10 min and then rinsed in distilled water.…”
Section: Experimental Studymentioning
confidence: 99%
“…Graft microgeometry was examined by Sudan Black staining with a procedure previously described . Briefly, graft samples were dipped in a staining solution (0.12% w/v in absolute ethanol) for 10 min and then rinsed in distilled water.…”
Section: Experimental Studymentioning
confidence: 99%
“…Graft microgeometry was highlighted by Sudan Black staining with a previously described procedure [21]. The stained surfaces were observed by a stereomicroscope (SZH0, Olympus, Milano, Italy) connected to a digital camera and representative images were acquired at 40 × magnification.…”
Section: Morphological Analysismentioning
confidence: 99%
“…SEM images were further processed using a computerized image analysis system (AxioVision Rel 4.6, Carl Zeiss, Jena, Germany). Briefly, circles were manually drawn following the perimeter of visible pores, and then the software calculated the average pores diameter [21].…”
Section: Morphological Analysismentioning
confidence: 99%
“…Scale bar: 100 ”m. B. Lipid staining with Sudan black B (Merck) was used to evaluate lipid droplets within adipocytes according to Soldani et al [61] on section from femur of 40 week-old DN-Erg mice. Scale bar: 50 ”m.…”
Section: Supporting Informationmentioning
confidence: 99%