2004
DOI: 10.1504/ijgei.2004.005894
|View full text |Cite
|
Sign up to set email alerts
|

Life Cycle Assessment (LCA) of Chinese energy chains for Shandong electricity scenarios

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2008
2008
2016
2016

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(10 citation statements)
references
References 6 publications
0
9
0
Order By: Relevance
“…One of the biggest causes of the large variation in supply chain emissions estimates is due to the assumed estimated ultimate recovery (EUR) of gas wells [16,23,54,134,135]. The EUR is the measure of economically feasible gas extraction and is dependent on the size of the well, the ease of extraction (i.e.…”
Section: Estimated Ultimate Recovery Of Wellsmentioning
confidence: 99%
“…One of the biggest causes of the large variation in supply chain emissions estimates is due to the assumed estimated ultimate recovery (EUR) of gas wells [16,23,54,134,135]. The EUR is the measure of economically feasible gas extraction and is dependent on the size of the well, the ease of extraction (i.e.…”
Section: Estimated Ultimate Recovery Of Wellsmentioning
confidence: 99%
“…The process for coal power was, moreover, based upon a study only describing 300 MW power plants in the Shandong province, with a thermal efficiency of 34.8% [11087] (Dones et al 2004). Ecoinvent also estimates a sulphur content of 0.9% (calculated using 1.7 kg SO 2 emission tonne -1 coal and 5% retained in the abatement of fly ashes) and NOx emissions of 9 kg tonne -1 coal combusted (Dones et al 2004). However, according to Zhao et al (2008) the national average sulphur content was 1.01% in 2005, with great spread amongst regions.…”
Section: Coal Miningmentioning
confidence: 99%
“…This analysis corrects the life cycle estimates based on the list of qualified life cycle studies developed by Sovacool (2008) by combining or eliminating redundant studies (Tables 1 and 2). A median emission per kWh of 38 g CO 2 /kWh is thereby obtained with upper and lower quartiles of 71 and 19 g CO 2 /kWh, respectively Table 4 of Sovacool (2008) was adjusted for redundant studies by averaging results for multiple studies by Dones et al (2003Dones et al ( , 2004Dones et al ( , 2005, averaging results for light and heavy water reactors by ISA (2006), and by using the more recent and more comprehensive study by Storm van Leeuwen and Smith (2007).…”
Section: Life Cycle Considerations For Adjusted Lag Timementioning
confidence: 99%