2023
DOI: 10.1080/10826076.2023.2223640
|View full text |Cite
|
Sign up to set email alerts
|

Library-based UHPLC-Q-exactive-orbitrap-MS putative identification of isomeric and non-isomeric bioactives from Zibushengfa Tablet and pharmacopeia quality-marker chemistry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
2

Relationship

4
3

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 74 publications
0
8
0
Order By: Relevance
“…In the current Pharmacopoeia (2020), there was only one ole Q-marker (23) for reliable HPLC analysis. Aa a result, the total characterizing rate (TCR) was 10.5% (2 ÷ 19); while the speci cally characterizing rate (SCR) was 0.0%, according to our recent de nition [17] . For new Q-markers system, the TCR and SCR values were calculated as 36.8% (7 ÷ 19) and 26.3% (5 ÷ 19), respectively.…”
Section: Uv-vis Spectra Scanning 34 Anti-counterfeiting Validation Ex...mentioning
confidence: 85%
“…In the current Pharmacopoeia (2020), there was only one ole Q-marker (23) for reliable HPLC analysis. Aa a result, the total characterizing rate (TCR) was 10.5% (2 ÷ 19); while the speci cally characterizing rate (SCR) was 0.0%, according to our recent de nition [17] . For new Q-markers system, the TCR and SCR values were calculated as 36.8% (7 ÷ 19) and 26.3% (5 ÷ 19), respectively.…”
Section: Uv-vis Spectra Scanning 34 Anti-counterfeiting Validation Ex...mentioning
confidence: 85%
“…To prevent a similar tragedy, a new principle named “non-industrialization” was recently proposed by our team [ 17 ]. According to the principle, one Q-marker candidate should not be easily obtained via industrialization.…”
Section: Discussionmentioning
confidence: 99%
“…In the current Pharmacopoeia (2020), there was only one ole Q-marker (23) for reliable HPLC analysis. Aa a result, the total characterizing rate (TCR) was 10.5% (2 ÷ 19); while the specifically characterizing rate (SCR) was 0.0%, according to our recent definition [ 17 ]. For new Q-markers system, the TCR and SCR values were calculated as 36.8% (7 ÷ 19) and 26.3% (5 ÷ 19), respectively.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Our team however established a database-a nity UHPLC-Q-Exactive-Orbitrap-MS/MS putative identi cation strategy [7,8] . This strategy could completely elucidate the MS fragment, and de nitely give stereo-con guration of chiral compounds, as well as clearly discriminate the isomers [9].…”
Section: Introductionmentioning
confidence: 99%