Portable Spectroscopy and Spectrometry 2021
DOI: 10.1002/9781119636489.ch25
|View full text |Cite
|
Sign up to set email alerts
|

Library and Method Development for Portable Instrumentation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 25 publications
0
1
0
Order By: Relevance
“…When determining the appropriate experimental conditions, we considered the importance of obtaining robust, high-quality spectra with minimal noise suitable for databases. Both sample-specific factors and environmental conditions were taken into account [29]. All measurements were carried out in a constant laboratory environment to minimize the impact on the signal-to-noise ratio (SNR) for a given exposure time.…”
Section: Spectral Data and Experimental Designmentioning
confidence: 99%
See 2 more Smart Citations
“…When determining the appropriate experimental conditions, we considered the importance of obtaining robust, high-quality spectra with minimal noise suitable for databases. Both sample-specific factors and environmental conditions were taken into account [29]. All measurements were carried out in a constant laboratory environment to minimize the impact on the signal-to-noise ratio (SNR) for a given exposure time.…”
Section: Spectral Data and Experimental Designmentioning
confidence: 99%
“…The camera features a state-of-the-art mercury cadmium telluride (MCT) detector and is equipped with a cryogenic cooling system, which ensures a constant temperature at 147 K. These characteristics enables low background noise, a high dynamic range, and an op- When determining the appropriate experimental conditions, we considered the importance of obtaining robust, high-quality spectra with minimal noise suitable for databases. Both sample-specific factors and environmental conditions were taken into account [29]. All measurements were carried out in a constant laboratory environment to minimize the impact on the signal-to-noise ratio (SNR) for a given exposure time.…”
Section: Ftirmentioning
confidence: 99%
See 1 more Smart Citation
“…Virtually all FT‐IR and Raman spectrometers, including handhelds, are configured with on‐board spectra‐search capability, and at minimum, a small library of materials [66]. The work involved in construction and assembly of these spectral libraries has been described in detail [67]. The library should encompass all the materials that might be encountered in the user scenario, and not just the target chemicals.…”
Section: Vibrational Spectroscopymentioning
confidence: 99%