1991
DOI: 10.1016/0958-3947(91)90055-7
|View full text |Cite
|
Sign up to set email alerts
|

Levels of leakage radiation from electron collimators of a linear accelerator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…7.42 (PTW Freiburg). Next, the off-axis ratios (OARs) on the cross-line (transverse direction) dose profiles were measured at a depth of 5 mm (R s ), the depth of dose maximum (R 100 ), the depth of a 90% dose (R 90 ), the depth of a 50% dose (R 50 ), and the practical range (R p ) as defined by AAPM TG25 [18] using a TM31010 (PTW Freiburg) thimble ionization chamber with an effective volume of 0.125 cm 3 . The doses measured at off-axis points of interest were normalized to the dose at the central beam axis in a water phantom for the given electron energy.…”
Section: Energy (Mev)mentioning
confidence: 99%
“…7.42 (PTW Freiburg). Next, the off-axis ratios (OARs) on the cross-line (transverse direction) dose profiles were measured at a depth of 5 mm (R s ), the depth of dose maximum (R 100 ), the depth of a 90% dose (R 90 ), the depth of a 50% dose (R 50 ), and the practical range (R p ) as defined by AAPM TG25 [18] using a TM31010 (PTW Freiburg) thimble ionization chamber with an effective volume of 0.125 cm 3 . The doses measured at off-axis points of interest were normalized to the dose at the central beam axis in a water phantom for the given electron energy.…”
Section: Energy (Mev)mentioning
confidence: 99%
“…For high‐energy electron beams, the out‐of‐field electron component is usually produced primarily via (2) and (3). For lower‐energy electron beams, scatter radiation occurs 12,13 . For 4‐MeV electron beams, the out‐of‐field dose peak may be caused by scattering electrons originating from the rounded surface of the MLC 14 .…”
Section: Discussionmentioning
confidence: 99%
“…For lower-energy electron beams, scatter radiation occurs. 12,13 For 4-MeV electron beams, the out-of-field dose peak may be caused by scattering electrons originating from the rounded surface of the MLC. 14 According to our results, the peripheral dose peak gradually weakened with an increasing number of LA layers, which was likely caused by the low penetration depth of the electron beams.…”
Section: D | Shielding Effect At 20-cm Depthmentioning
confidence: 99%
“…In addition to this, it is known that the part of the scattered and transmitted radiation that cannot be neglected leaks from the applicators and causes undesirable doses outside the treatment area. [5][6][7][8][9][10][11] The accuracy and efficacy of treatment in breast RT should involve accurate measurement of target and local surrounding tissue doses. Due to the excellent dosimetric properties, for example, the wide range of linearity of dose characteristic, the good lowest detection limit, near tissue equivalence and the low energy dependence the BeO detectors are predestined for dosimetric use.…”
Section: Introductionmentioning
confidence: 99%