2009
DOI: 10.1109/tns.2009.2016420
|View full text |Cite
|
Sign up to set email alerts
|

Level-2 Calorimeter Trigger Upgrade at CDF

Abstract: The CDF Run 11 [1] Level 2 calorimeter trigger is implemented in hardware and is based on a simple algorithm that was used in Run I. This system has worked well for Run II at low luminosity. As the Tevatron instantaneous luminosity increases, the limitation due to this simple algorithm starts to become clear. As a result, some of the most important jet and MET (Missing ET) related triggers have large growth terms in cross section at higher luminosity. In this paper, we present an upgrade of the L2CAL system wh… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
6
0

Year Published

2009
2009
2012
2012

Publication Types

Select...
5
1

Relationship

4
2

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 3 publications
0
6
0
Order By: Relevance
“…The first level requires two towers in the central calorimeter with E T > 5 GeV and two tracks with p T > 2 GeV/c reconstructed in the COT. The second level requires two energy clusters in the calorimeter with E T > 15 GeV and |η| < 1.5 [22], along with two tracks with p T > 2 GeV/c and impact parameter |d 0 | > 100 µm, characteristic of heavy flavor hadron decays, reconstructed using the level 2 silicon vertex trigger (SVT) system [23]. The third level confirms the level 2 silicon tracks and calorimeter clusters using a variant of the offline reconstruction.…”
Section: Data Sample and Event Selectionmentioning
confidence: 99%
“…The first level requires two towers in the central calorimeter with E T > 5 GeV and two tracks with p T > 2 GeV/c reconstructed in the COT. The second level requires two energy clusters in the calorimeter with E T > 15 GeV and |η| < 1.5 [22], along with two tracks with p T > 2 GeV/c and impact parameter |d 0 | > 100 µm, characteristic of heavy flavor hadron decays, reconstructed using the level 2 silicon vertex trigger (SVT) system [23]. The third level confirms the level 2 silicon tracks and calorimeter clusters using a variant of the offline reconstruction.…”
Section: Data Sample and Event Selectionmentioning
confidence: 99%
“…The selection of signal events proceeds as follows: a set of E / T -based triggers select events with a variety of E / T and jet requirements. All these triggers have benefited significantly from the calorimeter trigger upgrade completed in 2007 [16]. The majority (94%) of events satisfy the inclusive E / T trigger which requires E / T >45 GeV.…”
mentioning
confidence: 99%
“…Events are selected using a set of E / T -based triggers with a variety of E / T and jet requirements. All of these triggers have benefited significantly from a calorimeter trigger upgrade completed in 2007 [10]. The majority (94%) of events satisfy the inclusive E / T trigger which requires E / T > 45 GeV.…”
Section: Event Selectionmentioning
confidence: 99%