2010
DOI: 10.1007/s11999-009-1194-y
|View full text |Cite
|
Sign up to set email alerts
|

Letter to the Editor: Association of Osteonecrosis and Failure of Hip Resurfacing Arthroplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 13 publications
0
2
0
Order By: Relevance
“…In the pre-collapse stage, core decompression combined with and bone grafting should be chosen: Wei and Ge [ 3 ] reported a survivorship of 81% in a series of 162 patients with excellent results in 93.3% of cases in stage II and good results in 87% of the patients in stage III of Association Research Circulation Osseous. For late stages of the disease, THA, providing early pain relief and good functional outcome, is claimed to be the treatment of choice; however, some studies have reported high mechanical failure rates, indicating that osteonecrosis itself could represent a risk factor [ 4 6 ]. Osteolysis, as a result of polyethylene wear debris, remains one of the most important failure mechanisms in THA, and alternative bearing surfaces have been introduced in clinical practice to minimize the negative effects of wear on implant survival.…”
Section: Introductionmentioning
confidence: 99%
“…In the pre-collapse stage, core decompression combined with and bone grafting should be chosen: Wei and Ge [ 3 ] reported a survivorship of 81% in a series of 162 patients with excellent results in 93.3% of cases in stage II and good results in 87% of the patients in stage III of Association Research Circulation Osseous. For late stages of the disease, THA, providing early pain relief and good functional outcome, is claimed to be the treatment of choice; however, some studies have reported high mechanical failure rates, indicating that osteonecrosis itself could represent a risk factor [ 4 6 ]. Osteolysis, as a result of polyethylene wear debris, remains one of the most important failure mechanisms in THA, and alternative bearing surfaces have been introduced in clinical practice to minimize the negative effects of wear on implant survival.…”
Section: Introductionmentioning
confidence: 99%
“…We feel that when THAs are conducted in patients with AVN, certain critical precautions should be taken into account because this condition is considered a risk factor. According to Ortiguera et al [27], the dislocation rate in osteonecrosis patients is expected to be much higher than in osteoarthritic patients because subjects with AVN have potentially much less stiffness than patients with osteoarthritis and thus are able to achieve a wider range of hip movement after surgery, making them more prone to joint instability. Berry et al [28] examined the cumulative incidence of dislocation in a cohort of over 6000 prosthetic hips and found it to be more than doubled (14.1% compared to 6.4%) in patients with osteonecrosis than in those with osteoarthritis; their research also found that dislocation rates rise with extended durations of follow-up, possibly reflecting the impact of neuromuscular degeneration and, in particular, wear at the metal-on-polyethylene articulating surface.…”
Section: Amc-on-amc Total Hip Replacement In Avascular Necrosis Of Th...mentioning
confidence: 99%