2003
DOI: 10.1034/j.1600-0765.2003.00673.x
|View full text |Cite
|
Sign up to set email alerts
|

Lethal photosensitization of periodontal pathogens by a red‐filtered Xenon lamp in vitro

Abstract: The data indicate that PDT utilizing a conventional light source is at least as effective as laser-induced treatment in vitro. Furthermore, PDT achieves significant bactericidal activity in the presence of serum and blood when used with the set parameters of 10 J/cm2, 100 mW/cm2 and 12.5 micro g/ml TBO.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
48
0
5

Year Published

2005
2005
2018
2018

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 75 publications
(54 citation statements)
references
References 43 publications
1
48
0
5
Order By: Relevance
“…Matevski et al (28) found that a red-filtered xenon lamp was at least as effective as a laser for the photodynamic killing of P. gingivalis in vitro. Nevertheless, it is not known whether a single-wavelength laser or a broadspectrum light source would have provided better PDT effects in our study because multiple factors, such as O 2 saturation and serum in tissue, might affect the outcome of the therapy.…”
Section: Vol 49 2005 Pdt For Vibrio Vulnificus Infection 899mentioning
confidence: 99%
See 1 more Smart Citation
“…Matevski et al (28) found that a red-filtered xenon lamp was at least as effective as a laser for the photodynamic killing of P. gingivalis in vitro. Nevertheless, it is not known whether a single-wavelength laser or a broadspectrum light source would have provided better PDT effects in our study because multiple factors, such as O 2 saturation and serum in tissue, might affect the outcome of the therapy.…”
Section: Vol 49 2005 Pdt For Vibrio Vulnificus Infection 899mentioning
confidence: 99%
“…However, considerable heat will be generated at a low fluence rate with a broad-spectrum light source, such as the PDT-1200 lamp. Matevski et al (28) found that the heat generated with a red-filtered xenon lamp might compromise future clinical applications for the treatment of periodontal infections. Continuous cooling of the irradiated surface is thus necessary to lessen the hyperthermic effects and discomfort generated during irradiation with a fluence rate greater than 40 mW/cm 2 with the PDT-1200 lamp (T. W. Wong, unpublished data).…”
Section: Vol 49 2005 Pdt For Vibrio Vulnificus Infection 899mentioning
confidence: 99%
“…14 In endogenous PDT, the PDT e®ect depended on the endogenous photosensitizer porphyrin. [15][16][17] Endogenous PDT was safer than the exogenous one, because exogenous photosensitizer might have chemical toxicity and cause more side e®ects. 18,19 Endogenous PDT was much more commonly and e®ectively used in acne therapy.…”
Section: Discussionmentioning
confidence: 99%
“…The in vitro bactericidal effect of PDT on Gram-negative bacteria was also investigated and it was found to have a high bactericidal effect on Haemophilus parainfluenzae 34 , Prevotella and Porphyromonas species [35][36][37] , Helicobacter mustelae 38 , E. coli B, Acinetobacter baumannii, and P. aeruginosa 39,40 . PDT of Gram-positive and Gram-negative bacteria in animal models hasproven to be as successful as in in vitro studies in inactivating the causative bacteria [41][42][43][44][45][46] .…”
Section: Prophylactic Antimicrobials and Resistancementioning
confidence: 99%