2015
DOI: 10.4244/eijv11sva6
|View full text |Cite
|
Sign up to set email alerts
|

Lessons from the real bench: non-BRS

Abstract: Bench testing of stents used in bifurcations can provide information on the general properties that influence performance including crossing profile, radial strength, recoil, flexibility and radiopacity. Problems with device delivery can be clarified. Bench testing identified that side branch dilatation caused stent distortion and elucidated correction strategies. Bench testing led to a stent design change adding connectors between hoops to help overcome the clinical problem of longitudinal distortion. Testing… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2016
2016
2018
2018

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 27 publications
0
5
0
Order By: Relevance
“…BVSs offers an opportunity but also poses a challenge for PCI of CBLs because BVSs differ from the conventional metal stent platforms in many ways, such as the thicker struts and more fragile structure of the currently available BVS (PLLA-BVS). [ 31 ] In this way, the previous stenting techniques and associated procedural steps developed for metal stent platforms should be re-examined until they can be safely used with BVS.…”
Section: Discussionmentioning
confidence: 99%
“…BVSs offers an opportunity but also poses a challenge for PCI of CBLs because BVSs differ from the conventional metal stent platforms in many ways, such as the thicker struts and more fragile structure of the currently available BVS (PLLA-BVS). [ 31 ] In this way, the previous stenting techniques and associated procedural steps developed for metal stent platforms should be re-examined until they can be safely used with BVS.…”
Section: Discussionmentioning
confidence: 99%
“…The damage is one explanation for a balloon failing to cross through the side of a stent into a side‐branch. Other explanations include a wire exiting then re‐entering the stent lumen outside a strut . In addition, a lack of proximal optimization treatment (POT) may hinder crossing.…”
Section: Discussionmentioning
confidence: 99%
“…We believe that some stent designs such as those with small cells (the space between struts defined by hoops and connectors) or with complicated cell shape are more difficult to cross than those with larger cells . The more connectors there are between hoops, the smaller the cells and the more difficult they are to cross .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…When a provisional strategy is used, re-cross should ideally be performed through a distal stent cell. 12 This ensures that balloon inflation will produce better clearance of struts from the side branch ostium.…”
Section: Techniquementioning
confidence: 99%