2014
DOI: 10.4244/eijv10i3a60
|View full text |Cite
|
Sign up to set email alerts
|

Left ventricular contrast injection with rotational C-arm CT improves accuracy of aortic annulus measurement during cardiac catheterisation

Abstract: Cardiac catheterisation including LV-RCT offers complementary assessment of left ventricular function, aortic valve anatomy, coronary angiography and arterial access routes. LV-RCT for aortic root measurements shows better correlation to MDCT than standard Ao-RCT protocols.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 14 publications
0
5
0
Order By: Relevance
“…RCT was performed as part of the pre-implant diagnostic coronary angiography study[13]. The C-arm of the Cathlab system (Allura FD 20, 30 cm flat panel detector, XperCT option, Philips Healthcare, Andover, MA, United States) was rotated over an angular range of 210° with a sweep duration of 5.2 s and a frame-rate of 60 frames/s around the patient.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…RCT was performed as part of the pre-implant diagnostic coronary angiography study[13]. The C-arm of the Cathlab system (Allura FD 20, 30 cm flat panel detector, XperCT option, Philips Healthcare, Andover, MA, United States) was rotated over an angular range of 210° with a sweep duration of 5.2 s and a frame-rate of 60 frames/s around the patient.…”
Section: Methodsmentioning
confidence: 99%
“…Two independent, blinded observers performed aortic root diameter measurements in multiplanar reformatted RCT data sets at the level of the aortic annulus, the aortic sinus and the sino-tubular junction (STJ). These are supposed to be representative for the shape and dimensions of the aortic root anatomy to be overlaid to the fluoroscopic data stream for intervention guidance[13]. …”
Section: Methodsmentioning
confidence: 99%
“…41 Furthermore, compared to pre-procedural CT, the radiation and contrast exposure of CBCT is significantly lower. 11,22 TEE-XRF fusion is increasingly used in mitral valve repair and various CHD procedures. The major advantage is the use of real-time fusion of two important imaging modalities.…”
Section: Discussionmentioning
confidence: 99%
“…The reported radiation and contrast levels for CBCT are significantly lower than the median radiation exposure used in adult cardiac CT, especially with optimized CBCT protocols. [10][11][12][13][14][15] When used only for anatomical guidance during HI, CBCT is therefore the preferred modality. Moreover, a beneficial effect of CBCT + XRF-based interventions compared to XRF interventions alone on skin dose is seen in patients.…”
Section: Peri-procedurally Acquired Imagingmentioning
confidence: 99%
See 1 more Smart Citation