1974
DOI: 10.1016/s0022-5223(19)41629-2
|View full text |Cite
|
Sign up to set email alerts
|

Left ventricular and unidirectional intra-aortic balloon pumping

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
4
0
1

Year Published

1976
1976
2019
2019

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 25 publications
0
4
0
1
Order By: Relevance
“…Although multiple animal trials have been previously conducted to evaluate the feasibility of IVBPs, only a few in vitro studies have analyzed intraventricular assist devices with a pulsatile chamber. [5][6][7][8] The advantage of using a purpose-built MCL as opposed to animal trials lays in the cost, testing condition repeatability, and adaptability. Previous IVBP studies have tested flexible balloons for LV implantation in animal models with different volumes (from 40 to 110 mL) and geometries, such as: spherical, tomato, pear, and an LV cast at end-diastole.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Although multiple animal trials have been previously conducted to evaluate the feasibility of IVBPs, only a few in vitro studies have analyzed intraventricular assist devices with a pulsatile chamber. [5][6][7][8] The advantage of using a purpose-built MCL as opposed to animal trials lays in the cost, testing condition repeatability, and adaptability. Previous IVBP studies have tested flexible balloons for LV implantation in animal models with different volumes (from 40 to 110 mL) and geometries, such as: spherical, tomato, pear, and an LV cast at end-diastole.…”
Section: Discussionmentioning
confidence: 99%
“…Previous IVBP studies have tested flexible balloons for LV implantation in animal models with different volumes (from 40 to 110 mL) and geometries, such as: spherical, tomato, pear, and an LV cast at end-diastole. 6,8,10,12,13 Interestingly, only 1 study has customized the balloon volume to the LV shape: Stamatelopoulos et al evaluated 3 balloon volumes (LVEDV and LVEDV ± 25%) on IVBP function. 13 Results indicated that an intraventricular balloon volume equal to the corresponding LVEDV generated the largest MAP and AoF.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…-ο κυβισμός του αεροθαλάμου -το σχήμα του αεροθαλάμου -η θέση του αεροθαλάμου μέσα στην αριστερά κοιλία -η διάρκεια εκπτύξεως του αεροθαλάμου -η συχνότητα λειτουργίας του αεροθαλάμου -το είδος του χρησιμοποιουμένου αερίου Β. Βιολογικές παράμετροι: -η αντίσταση πληρώσεως του αρτηριακού συστήματος -η διατασιμότητα-ενδοτικότητα του τοιχώματος της αριστεράς κοιλίας -ο υπάρχων ενδαγγειακός όγκος Από αυτές, έχουν ελεγχθεί η συχνότητα λειτουργίας του αεροθαλάμου 22 , η θέση του αεροθαλάμου μέσα στην αριστερά κοιλία 41 και η αντίσταση πληρώσεως του αρτηριακού συστήματος 56 . Εχει δειχθεί δε ότι η ιδανική συχνότητα λειτουργίας του αεροθαλάμου είναι 75 κύκλοι ανά λεπτό 22 , ενώ η θέση του μέσα στην αριστερή κοιλία πρέπει να είναι τέτοια που να μην προκαλεί απόφραξη ή δυσλειτουργία της μιτροειδούς βαλβίδας 22 • 41 . Επίσης παρατηρήθηκε 56 ότι η αύξηση του μεταφορτίου της αριστεράς κοιλίας με φαρμακευτική πρόκληση αγγειοσύσπασης επέφερε μεν αύξηση της συστολικής αρτηριακής πίεσης, μείωνε όμως την παροχή της αριστεράς κοιλίας και αύξανε την παλινδρόμηση διά του στομίου της μιτροειδούς.…”
Section: συστήματα εξωσωματικής οξυγόνωσης και καρδιοπνευμονικής παράκαμψηςunclassified