1977
DOI: 10.1107/s0021889877012680
|View full text |Cite
|
Sign up to set email alerts
|

Least-squares structure refinement based on profile analysis of powder film intensity data measured on an automatic microdensitometer

Abstract: The Rietveld profile‐analysis refinement procedure [Rietveld, J. Appl. Cryst. (1969), 2, 65–71] is here applied to microdensitometer‐measured Guinier–Hägg X‐ray powder film data (strictly monochromated Cu Kα1 radiation). Various functions for describing the profile form of an individual reflection are tested; the most satisfactory fit is obtained for a modified and asymmetrized Lorentz function. The crystal structure of α‐Bi2O3 has been refined and no significant deviations are observed from the results of an … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
68
0
5

Year Published

1979
1979
2017
2017

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 156 publications
(74 citation statements)
references
References 5 publications
(11 reference statements)
1
68
0
5
Order By: Relevance
“…The procedure for refinement of a two-component system follows exactly that used for the single-component case: see Rietveld (1969) and Malmros & Thomas (1977), hereafter: MT. The combined data file is created in a preparation program where all pertinent input information needed for the individual components is supplied in sequence.…”
Section: The Analysis Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The procedure for refinement of a two-component system follows exactly that used for the single-component case: see Rietveld (1969) and Malmros & Thomas (1977), hereafter: MT. The combined data file is created in a preparation program where all pertinent input information needed for the individual components is supplied in sequence.…”
Section: The Analysis Methodsmentioning
confidence: 99%
“…There is also a widespread need for experimental techniques for performing structural studies where single-phase powder cannot be obtained. It is clear that the full-profile analysis procedure of Rietveld (1969) can find an application in both fields; particularly the technique as applied to microdensitometermeasured Guinier-H~igg X-ray powder film data (Malmros & Werner, 1973;Malmros & Thomas, 1977;Berg & Werner, 1977). The latter method has the great advantage that it requires extremely small amounts of powder (down to 0-2 mg) and, in as much as it takes full account of overlap, it makes optimal use of the data available.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Dramatic expansion in the use of the method followed construction of the first wave of h;gh-resolution single-wavelength (Hewat, 1975) and time-of-flight (Jorgensen & Rotella, 1982) neutron powder diffractometers. Extension to conventional X-ray data (Malmros & Thomas, 1977;Young, Mackie & Von Dreele, 1977;Wiles & Young, 1981) provided the catalyst for its increased usage in the wider crystallographic community, while the most recent new application has involved the use of X-rays from synchrotron sources (Cox, Hastings, Thomlinson & Prewitt, 1983;Parrish, Hart & Huang, 1986).…”
Section: Introductionmentioning
confidence: 99%
“…Reviews of this technique have been given by Cheetham & Taylor (1977) and, more recently, by Albinati & Willis (1982). There is now also considerable interest in structure refinement from X-ray powder diffraction patterns and a number of papers (Malmros & Thomas, 1977;Young, Mackie & Von Dreele, 1977;Khattak & Cox, 1977;Wiles & Young, 1981;Young & Wiles, 1982) have discussed applications of Rietveld refinement to X-ray diffraction. The methods tried, unfortunately, have so far met with only limited success, the major problem being in obtaining an adequate description of the peak shape of the diffraction line and its variation with Bragg angle.…”
Section: Introductionmentioning
confidence: 99%