Least squares best fit line method for the evaluation of measurement uncertainty with electromechanical transducers (EMT) with Electrical Outputs (EO)

Abstract: In the electromechanical type indirect pressure indicating devices (IPIDs), the applied pressure is indirectly computed by some relationship between applied pressure and an analog / digital electrical signal in terms of voltage, current or frequency measured by a sensing element of such devices. If the output of an EMT in terms of any electrical quantity i.e. voltage, current or frequency, is related / dependent upon input quantity i.e. pressure then this relationship can be defined by a curve that has been fi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
4
2

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 7 publications
(11 reference statements)
0
6
0
Order By: Relevance
“…The critical importance of addressing uncertainty in scientific measurements have been discussed at length by various researchers [31][32][33]. Uncertainties in validation of this model might originate from: (1) Rooms were made airtight by tightly closing doors and windows and blocking visible gaps under doors and windows etc., but engineered leak-proofing techniques was not followed, (2) operation of ceiling/pedestal fans may not guarantee perfect homogeneous mixing of indoor CO 2 , (3) CO 2 detectors have certain accuracy levels and hence have inherent uncertainty in measurements.…”
Section: Resultsmentioning
confidence: 99%
“…The critical importance of addressing uncertainty in scientific measurements have been discussed at length by various researchers [31][32][33]. Uncertainties in validation of this model might originate from: (1) Rooms were made airtight by tightly closing doors and windows and blocking visible gaps under doors and windows etc., but engineered leak-proofing techniques was not followed, (2) operation of ceiling/pedestal fans may not guarantee perfect homogeneous mixing of indoor CO 2 , (3) CO 2 detectors have certain accuracy levels and hence have inherent uncertainty in measurements.…”
Section: Resultsmentioning
confidence: 99%
“…However, our observations reveal that 8th order fit is most suitable in such cases [ Fig.3(d)]. In such cases, the uncertainty of the calibration curve is estimated from the calibration coefficients [24][25] and is root-sumsquares of residuals obtained as suggested above for the computation of the overall uncertainty associated with pressure measurement.…”
Section: Resultsmentioning
confidence: 99%
“…The uncertainty budget [5][6] for calibration of strain amplifier with load cell is given in Table 3.…”
Section: Measurement Resultsmentioning
confidence: 99%