2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) 2015
DOI: 10.1109/iros.2015.7354172
|View full text |Cite
|
Sign up to set email alerts
|

Learning gait by therapist demonstration for natural-like walking with the CORBYS powered orthosis

Abstract: The number of mechanical degrees of freedom (DoFs) within rehabilitation robots directly influences the scope of the movements that a subject can perform when training walking. Currently, gait rehabilitation robots have a limited number of mechanical DoFs, as a consequence this limits the movements these robots can make possible. In this paper, the novel gait rehabilitation system CORBYS is presented which consists of the mobile platform and a powered orthosis which is attached to the platform. The CORBYS powe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2016
2016
2018
2018

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 6 publications
0
3
0
Order By: Relevance
“…The principle of this step is to select the reference dataset which is less affected by noise and potentially gives the most promising segmentation result as the reference for performing the segmentation. The selecting criterion is given by (5). Segmentation on the optimal reference dataset should minimize the variance of cycle length.…”
Section: B) Find a Dataset To Be The Segmentation Referencementioning
confidence: 99%
See 1 more Smart Citation
“…The principle of this step is to select the reference dataset which is less affected by noise and potentially gives the most promising segmentation result as the reference for performing the segmentation. The selecting criterion is given by (5). Segmentation on the optimal reference dataset should minimize the variance of cycle length.…”
Section: B) Find a Dataset To Be The Segmentation Referencementioning
confidence: 99%
“…The reliability of segmentation is essential for further analysis and directly influences the quality of analysis results of gait. Additionally, pathological gait tends to have more noisy data, which makes the gait cycle segmentation more challenging [5].…”
Section: Introductionmentioning
confidence: 99%
“…From the point of view of medical practitioners, rehabilitation robotics has been mainly concentrated on helping the patient to do exercises in virtual environments (as in upper limb rehabilitation with InMotion2 or ArmeoSpring robots) or even without any stimulating environment as in many robotic devices dedicated to gait rehabilitation. More recently, [7] studied an intelligent tutoring system for a gait rehabilitation robotic system by automatically learning from the therapist. These robots are usually very expensive and only dedicated to rehabilitation units in hospitals.…”
Section: B Use Of Robots In Medical Rehabilitationmentioning
confidence: 99%