2017
DOI: 10.1016/j.applthermaleng.2017.04.148
|View full text |Cite
|
Sign up to set email alerts
|

Leakage characteristics and an updated volumetric efficiency prediction model of rolling piston type rotary compressor for small capacity air-conditioner and heat pump applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 35 publications
(11 citation statements)
references
References 24 publications
0
6
0
1
Order By: Relevance
“…[3,4] In past decades, many scholars would pay more attention to different types of leakage losses in the cylinder to enhance the thermal performance and improve the efficient of rotary compressor system. Cai et al [5,6] and He et al [7] conducted a theoretical method to calculate several kinds of leakage losses in rotary compressor and proposed the experimental investigation to compare the theoretical results with experimental results, which proved the validity of theoretical method. Pan et al [8] presented a method to analyze leakage mass flow rate of six different leakage patterns, furthermore, verified the simulated results by monitoring the errors between the theoretical refrigerant mass flow rate and the experimental refrigerant mass flow rate.…”
Section: Introductionmentioning
confidence: 86%
“…[3,4] In past decades, many scholars would pay more attention to different types of leakage losses in the cylinder to enhance the thermal performance and improve the efficient of rotary compressor system. Cai et al [5,6] and He et al [7] conducted a theoretical method to calculate several kinds of leakage losses in rotary compressor and proposed the experimental investigation to compare the theoretical results with experimental results, which proved the validity of theoretical method. Pan et al [8] presented a method to analyze leakage mass flow rate of six different leakage patterns, furthermore, verified the simulated results by monitoring the errors between the theoretical refrigerant mass flow rate and the experimental refrigerant mass flow rate.…”
Section: Introductionmentioning
confidence: 86%
“…Comparing both models, Cai et al [114] concluded experimentally that no leakage model can single-handedly model the leakage across the wide range of operating and geometric variations. Subsequently, a semi-empirical two-phase leakage flow model was formulated, providing greater accuracy than theoretical flow models [115].…”
Section: Internal Leakagementioning
confidence: 99%
“…Dünya nüfusunun artışı ve teknolojinin gelişmesi ile birlikte özellikle gelişmekte olan ülkelerde enerjiye duyulan ihtiyaç ve enerji tüketimi her geçen gün dramatik bir şekilde artmaktadır [1][2][3][4]. Birçok endüstriyel tesiste basınçlı hava sistemleri, elektrik enerji tüketiminde 3. sırada yer almaktadır.…”
Section: Gi̇ri̇ş (Introduction)unclassified