2013
DOI: 10.1016/j.ijggc.2013.09.018
|View full text |Cite
|
Sign up to set email alerts
|

Leak detection of CO2 pipelines with simple atmospheric CO2 sensors for carbon capture and storage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 23 publications
(6 citation statements)
references
References 7 publications
0
6
0
Order By: Relevance
“…Furthermore, typical emission factors used as the default values in inventories can hardly be representative of the specific configurations and processes of individual sites, and, in practice, they are usually different from those measured at specific sites (e.g. Vaughn et al, 2017;Ravikumar and Brandt, 2017;Omara et al, 2018) Monitoring of CH 4 emissions from individual sites and even at the scale of local facilities within the same site is thus recommended to assess the effectiveness of local measures applied to minimize emissions (Konschnik and Jordaan, 2018).…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, typical emission factors used as the default values in inventories can hardly be representative of the specific configurations and processes of individual sites, and, in practice, they are usually different from those measured at specific sites (e.g. Vaughn et al, 2017;Ravikumar and Brandt, 2017;Omara et al, 2018) Monitoring of CH 4 emissions from individual sites and even at the scale of local facilities within the same site is thus recommended to assess the effectiveness of local measures applied to minimize emissions (Konschnik and Jordaan, 2018).…”
Section: Introductionmentioning
confidence: 99%
“…Another method to detect leaks from a CCS site is using multiple CO 2 sensors as described by (Luhar et al, 2014;van Leeuwen et al, 2013). This principle is also demonstrated when comparing the two different CO 2 measurements in the small and main tower during the release experiment on September 11 and September 12, 2014.…”
Section: Discussionmentioning
confidence: 99%
“…If this is the case, at least one additional measurement point is necessary to establish the background concentration (Leuning et al, 2008;Luhar et al, 2014;van Leeuwen et al, 2013).…”
Section: Introductionmentioning
confidence: 99%
“…For this purpose, it measures the temperature with an internal sensor and accepts user inputs for pressure and humidity. Shusterman et al (2016) andvan Leeuwen et al (2013) found some residual dependencies of the sensor output to temperature, pressure, and humidity and proposed to derive an empirical correction which can be specific for a sensor unit.…”
Section: Co 2 Sensor Characterizationmentioning
confidence: 99%