2017
DOI: 10.1007/978-3-319-59129-2_2
|View full text |Cite
|
Sign up to set email alerts
|

Leaflet Free Edge Detection for the Automatic Analysis of Prosthetic Heart Valve Opening and Closing Motion Patterns from High Speed Video Recordings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…This change-of-view also allowed for falsely-segmented areas from the axial view thresholding steps to be removed producing a clear picture of the tricuspid valve pattern in three-dimensions. The resulting segmented volume was then subsequently dilated 5 in preparation for thinning 5,11 during the design-fixing stage of processing. Dilation 5 of the image data extends any highlighted data point outward to its nearest neighbouring pixels in the axial, sagittal and coronal slices in accordance with the expression 5…”
Section: Aortal Valve Segmentationmentioning
confidence: 99%
See 2 more Smart Citations
“…This change-of-view also allowed for falsely-segmented areas from the axial view thresholding steps to be removed producing a clear picture of the tricuspid valve pattern in three-dimensions. The resulting segmented volume was then subsequently dilated 5 in preparation for thinning 5,11 during the design-fixing stage of processing. Dilation 5 of the image data extends any highlighted data point outward to its nearest neighbouring pixels in the axial, sagittal and coronal slices in accordance with the expression 5…”
Section: Aortal Valve Segmentationmentioning
confidence: 99%
“…Next, a higher threshold of [-600, 170] was applied in order to incorporate the brighter pixel platescale of the valve tissue into the model. Due to a large amount of calcification observed on the With the calcified region then highlighted to be included in the 3D rendering, it was then possible to observe the three aortic valve cusps and the tricuspid pattern where individual valve cusps partially overlap and occlude each other 11 . Using an axial view of the segmented valve, further enhancement of the tricuspid pattern was applied using Slicer 4.8.1's paint tool for a spherical brush of radius 1.400mm along the tricuspid lines of occlusion for a threshold range of [170,190] between the axial slices -977.768mm to -957.270mm.…”
Section: Aortal Valve Segmentationmentioning
confidence: 99%
See 1 more Smart Citation