1996
DOI: 10.1111/j.1540-8159.1996.tb03418.x
|View full text |Cite
|
Sign up to set email alerts
|

Lead Fracture in Cephalic Versus Subclavian Approach with Transvenous Implantable Cardioverter Defibrillator Systems

Abstract: Lead fracture, occurring in approximately 1%-4% of patients, is an infrequent, but potentially catastrophic complication of permanent pacing systems. Its incidence in transvenous defibrillator systems has not been established. We analyzed data from 757 patients undergoing implantation of transvenous cardioverter defibrillator systems using the Medtronic Transvene Lead system between October 20, 1989 and June 25, 1992 to determine if site of venous approach influenced incidence of lead fracture. All patients re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
44
0

Year Published

1998
1998
2018
2018

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 74 publications
(45 citation statements)
references
References 20 publications
1
44
0
Order By: Relevance
“…Six out of those seven had X-ray manifestations of lead fracture. In the same study, of the 221 leads that were placed via the cephalic vein, there were no lead fractures noted [3]. Patients with lead fracture may present with increasing pacer threshold, loss of capture, or inappropriate shocks in presence of a transvenous defibrillator.…”
Section: Discussionmentioning
confidence: 97%
“…Six out of those seven had X-ray manifestations of lead fracture. In the same study, of the 221 leads that were placed via the cephalic vein, there were no lead fractures noted [3]. Patients with lead fracture may present with increasing pacer threshold, loss of capture, or inappropriate shocks in presence of a transvenous defibrillator.…”
Section: Discussionmentioning
confidence: 97%
“…4) Another point of frequent fracture occurrence is near the anchoring sleeve. Special attention should be given to positioning the sleeve as parallel to the leads as possible, thereby avoiding lead bends and unnecessary stress inside the pectoral pocket for the generator.…”
Section: Discussionmentioning
confidence: 99%
“…[3][4][5] Lead fractures alone are less common, 0.9% in the series of Gallik et al 4 Two particular sites of lead fracture were noted, i.e. one at the clavicle, first rib junction, and the other within the generator pocket.…”
Section: Discussionmentioning
confidence: 99%